POWER SOURCE HANDLING & POSITIONING
Locate your Forney 250P+ Plasma System near a 120VAC power receptacle.
Should an extension cord be required, Forney suggests a 120V, 1-Phase extension cord with
a 10 AWG gauge size up to a maximum of 50 feet in length.
Choose location verifying that there is a good air flow and no dust, smoke or gas is present.
Place the unit on a flat and stable surface.
Make sure that obstacles do not prevent the cooling air flow out of front and rear openings
of the machine.
Arrange an open space of at least 15 feet (5m) around the machine.
In the case the machine has to be moved, always disconnect the plug from the outlet and
gather the cables so as not to damage them.
REQUIREMENTS FOR GROUNDING
To ensure personal safety, proper operation, and to reduce electromagnetic interference
(EMI), the Forney 250P+ must be properly grounded.
The power supply must be grounded through the power cord according to national and local
electrical standards.
Single-phase service must be of the 3-wire type with a green or green/yellow wire for the
protective earth ground. Do not use 2-wire service.
AIR/GAS SUPPLY
• Your Forney 250P+ Plasma System includes a built-in piston air compressor; therefore, you
have no need for a shop air source or compressed gas cylinders to operate your system
successfully.

Torch Assembly (if required)

USE ONLY TORCHES SPECIFIED IN THIS INSTRUCTIONS MANUAL.
CAUTION! Disconnect power source before assembly / disassembly of the torch.
BEFORE STARTING THE CUTTING OPERATIONS VERIFY THAT THE PARTS ARE
PROPERLY ASSEMBLED BY INSPECTING THE HEAD OF THE TORCH AS SHOWN
BELOW.
INSTANT-ON TORCHES, PLASMA ARC CAN CAUSE INJURY AND BURNS.
CAUTION! The plasma arc comes on immediately when the torch trigger is activated. Make
sure the power is off and the machine disconnected before changing consumables.
PROPERLY ASSEMBLED PLASMA TORCH
In the event that your plasma torch consumable parts are not already assembled, use the
following procedure:
14
PROPER ASSEMBLY SEQUENCE OF PLASMA CONSUMABLES
WWW.FORNEYIND.COM