This product is suitable for use in living areas, and Bathroom
dry (Outside) Zones only (see diagram below and current
IET Wiring Regulations for details). It is not suitable for
Bathroom Zones 0,1, or other areas where contact with
moisture is likely. If being fitted in a bathroom a 30mA RCD
must be used. This appliance does not come fitted/supplied
with a fused plug. DO NOT wire/fit a plug to this appliance.
The appliance must be electrical connected to a fused fixed
spur, which is fitted with a 13Amp fuse.
Always refer to the Reference Drawing for Bathroom
Installation.
Note: the below drawing is for reference only.
We suggest you to contact a professional electrician for any
help.
ZONE
1
2.25m
ZONE
THIS PRODUCT IS SUITABLE FOR BATHROOMS
ZONE 2 AND OUTSIDE ZONE;
* Full details can be found in the current IET Wiring
Regulations (BS7671)
(DRY) OUTSIDE ZONES