Fault
The pump doesn't start.
The pump switches itself off.
The water separator container
cannot be removed.
10. Disposal
Most of the materials from which Hilti tools or appliances are manufactured can be recycled. The materials must
be correctly separated before they can be recycled. In many countries, Hilti has already made arrangements
for taking back old tools and appliances for recycling. Ask Hilti customer service or your Hilti representative
for further information.
For EC countries only
Disposal of electric appliances together with household waste is not permissible.
In observance of European Directive 2002/96/EC on waste electrical and electronic equipment and
its implementation in accordance with national law, electric appliances that have reached the end
of their life must be collected separately and returned to an environmentally compatible recycling
facility.
11. Manufacturer's warranty
Hilti warrants that the tool supplied is free of defects
in material and workmanship. This warranty is valid
so long as the tool is operated and handled correctly,
cleaned and serviced properly and in accordance with
the Hilti Operating Instructions, and the technical
system is maintained. This means that only original
Hilti consumables, components and spare parts may
be used in the tool.
This warranty provides the free-of-charge repair or
replacement of defective parts only over the entire
lifespan of the tool. Parts requiring repair or replace-
Possible cause
Electric power failure.
The pump is defective.
The overheating cut-out has been
activated.
The system is still under vacuum.
ment as a result of normal wear and tear are not
covered by this warranty.
Additional claims are excluded, unless stringent na-
tional rules prohibit such exclusion. In particular,
Hilti is not obligated for direct, indirect, incidental
or consequential damages, losses or expenses in
connection with, or by reason of, the use of, or
inability to use the tool for any purpose. Implied
warranties of merchantability or fitness for a par-
ticular purpose are specifically excluded.
Remedy
Check the fuses and cables.
Check the position of the switch.
Check that the electric supply
voltage complies with the details
given on the rating plate.
Return the appliance for repair.
Allow the appliance to cool down.
The appliance switches on again
automatically.
Check the ventilation slots and clean
them if necessary.
Check the operating voltage.
Release the pressure by connecting
the hose to the vacuum baseplate.