TECHNICAL SERVICE
REPLACEMENT OF THE PUMP BODY ASSEMBLY
1.
Follow steps 1 and 2 of the previous paragraph.
2.
Place the pump with te correct side up and remove the three screws from the bottom of the container.
3.
Remove the pump body.
4.
Place the new body in position and screw the outlet valve without tightening.
5.
Introduce the axe of the pedal in its bearing and screws the three screws situated on the bottom part of the container.
6.
Tighten the outlet valve.
Fig. 1
Fig. 3

TROUBLESHOOTING

SYMPTOMS
Grease exits through the top part of the pump.
When applying pressure on the foot lever, grease does not
come out, or the flow diminishes.
The pedal does not return to its original position.
Alentec & Orion AB Grustagsvägen 4, SE-13840, Älta, SWEDEN · info@alentec.se · www.alentec.com
Fig. 2
POSSIBLE CAUSES
The piston joint is damaged.
The outlet valve is damaged.
There is dirt in the outlet valve seat.
The piston is damaged.
The torsion spring is broken.
Fig. 4
SOLUTIONS
Replace as per indications in paragraph: "technical
service".
Replace the outlet valve.
Cleaning of the seat.
Replace body valve assembly as per indications
Replace as per indications in paragraph: "technical
service".