If further assistance is required, please contact: Product support at 1.866.907.0122 (09:00 - 17:00hrs PST) or email technical@blubathworks.com North America Blu Bathworks Inc. 188 Smithe Street, Vancouver BC, Canada, V6B 6A9 T+1.604.299.0122 F+1.604.299.0125 Please refer to blubathworks.com for warranty, terms & conditions under warranty & procedure for warranty service.
Página 4
ATTENTION VERY IMPORTANT PLACE THE CONNECTORS WITH NON -RETURN VALVE AND SHUT-OFF DEVICE FOR THERMOSTATIC TX902 ATTENTION VERY IMPORTANT PLACE THE CONNECTORS WITH NON-RETURN VAL VE AND SHUT-OFF DEVICE FOR THERMOSTATIC TX902 2017-07 blubathworks.com ®...
Página 5
5½" [139] 1½" 4" [35] [104] 2" ATTENTION [50] • VERY IMPORTANT PLACE THE ROUGH-IN WITH THE MEASURES INDICATED 1¼" MAX hole size [30] on the finished wall. * Take care NOT to scratch the rough-in sleeve while cutting the plastic mud guard. 2"...
Página 6
EN - INSTALLATION GUIDE Position the cover (1) on the wall. Screw the lever (2) on to the water opening/closing control ring (3). Insert the temperature control knob (4) so that the lock button is in the vertical position, fixing it with the special screw (5) supplied. Insert the closing cap (6) securing it with the grub screw (7) using a 1.5 mm Allen key supplied.
Página 7
EN - MAINTENANCE Remove the grub screw (1) using the 1.5 mm Allen key supplied. Remove the cap (2). Unscrew the screw (3) with a 2.5 mm Allen key. Remove the handle (4) and latch ring temperature (5) and the command handle for opening and closing the water (6). With a 36mm/1 3/8" wrench unscrew the locking ring (7).