Product support at 1.866.907.0122 (09:00 - 17:00hrs PST) or email technical@blubathworks.com North America Blu Bathworks Inc. 188 Smithe Street, Vancouver BC, Canada, V6B 6A9 T + 1.604.299.0122 F+ 1.604.299.0125 Please refer to blubathworks.com for warranty, terms & conditions under warranty & procedure for warranty service.
Página 4
A TTENTION VERY IMPORTANT PLACE THE CONNECTORS WITH NON -RETURN VALVE AND SHUT-OFF DEVICE FOR THERMOSTATIC TX901 (Not Provided) (Not Provided) ATTENTION VERY IMPORTANT PLACE THE CONNECTORS WITH NON-RETURN VAL VE AND SHUT-OFF DEVICE FOR THERMOSTATIC TX901 Filter screens for inlets are required (not provided). If the above conditions are neglected, the product efficiency may vary.
Página 5
[119] [84] 1½" [35] [10] 4" 2¼" ATTENTION • [59] [100] VERY IMPORTANT PLACE THE ROUGH-IN MAX hole size 1¼" WITH THE MEASURES INDICATED [30] on the finished wall. 2" * Take care NOT to scratch the rough-in [49] sleeve while cutting the plastic mud guard. 3"...
Página 6
EN - INSTALLATION GUIDE Install the valve with plaster guard fully attached, and tile around it between the min/max marks accordingly. When ready to install trim, cut off invisible plaster guard with the knife, cutting the plastic flush to the wall. Position the ring (1) on the wall. Insert the handle (2).
Página 7
EN - MAINTENANCE Unscrew the lever (1) and the grub screw (2) using the supplied allen wrench (3). Remove the handle (4). Unscrew the ring nut (5). Replace the cartridge (6) inside the tap body (7). Lock the cartridge with the tightening ring nut (5). Insert the handle (4).