Focal Length Selection And Focus Adjustment - Velleman CAMCOLBUL34 Manual Del Usuario

Cámara cilíndrica 1/3" con 36 leds ir,alta resolución y lente varifocal
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

5.
Overview
Refer to the illustrations on page 2 of this manual.
1 IR LEDs
2 sun shield
3 bracket
4 lens
5 bracket screw holes
6.
Installation
1.
Choose a location for the camera, keeping following guidelines in mind:
do not install the camera in locations where extremely high or low temperatures or excessive
o
vibrations may occur.
avoid mounting the camera near high electro-magnetic fields.
o
do not aim the camera at the sun or other extremely bright objects or reflections (e.g. metal
o
doors).
2.
Use the mounting bracket [3] to determine the location of the mounting holes. Drill the holes and
secure the bracket using 3 screws [5].
3.
Remove the joint [6] from the bracket.
4.
Connect the camera bolt [7] of the joint to the back of the camera.
Note: there are two screw holes [9] for the camera bolt on the back of the camera. Choose the one
that best suits your installation location.
5.
Re-attach the joint (with the camera) to the mounting bracket.
6.
Connect the power connector [B] to the 12 VDC power supply (not incl.).
7.
To ensure the camera is sufficiently protected against moisture, cover the power and video
connectors (for example using insulating tape).
8.
Connect the BNC connector [A] to a monitor (not incl.).
9.
Point the camera towards the field of interest and tighten the position bolt [8].
7.

Focal Length Selection and Focus Adjustment

Notes:
We recommend adjusting the focal length and focus at an ambient temperature between
0 and 40 °C.
Finish the adjustment as quickly as possible (max. 10 minutes) to prevent that excess humidity
builds up inside the camera, and the desiccants absorb too much moisture and are unable to keep
the camera dry.
Avoid adjusting in a high moisture environment. If this is not possible, then finish the adjustment as
quickly as possible.
To adjust focal length and focus, proceed as follows:
1.
Open the front cover [10] of the camera by rotating it counter-clockwise.
Inside the camera, you see two handles to adjust the focal length [11] and focus [12].
2.
Focal length selection: loosen the screw of the handle [11], rotate to find the optimal surveillance
area [13], then tighten the screw again.
3.
Focus: loosen the screw of the handle [12], rotate until the image is in focus, then tighten the
screw again. For an optimal focus adjustment, we recommend:
For ambient temperatures < 15 °C, aim the camera at an object 15 m away from the camera
o
for focus adjustment.
For ambient temperatures > 35 °C, aim the camera at an object 5 m away from the camera for
o
focus adjustment.
For ambient temperatures between 15 and 35 °C, aim the camera at the view you want to see
o
for focus adjustment.
4.
Find the desiccants (incl.) and place them in the camera as shown in the illustration [14].
5.
Immediately replace the front cover of the camera and turn it clock-wise to fasten it.
Note: Make sure the front cover is fastened well to prevent moisture from entering the camera.
6.
Slide the sun shield over the camera [15].
V. 01 – 18/11/2013
CAMCOLBUL34
6
joint
7
camera bolt
8
position bolt
9
camera screw holes
10 camera front cover
4
11 focal length screw
12 focus screw
13 focal length adjustment
14 desiccant
15 sun shield installation
©Velleman nv