PowerBoss 030647 Manual Del Operario página 11

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operation Location of Portable Generator to
REDUCE THE RISK OF FIRE
WARNING Exhaust heat/gases could ignite
combustibles, structures or damage fuel
tank causing a fire, resulting in death or
serious injury.
• Portable generator must be at least 1.5 m (5 ft.) from
any structure, overhang, trees, windows, doors, any wall
opening, shrubs, or vegetation over 30.5 cm (12 in.) in
height.
• DO NOT place portable generator under a deck or other
type of structure that may confine airflow.
• Smoke alarm(s) MUST be installed and maintained
indoors according to the manufacturer's instructions/
recommendations. Carbon monoxide alarms cannot
detect smoke.
• DO NOT place portable generator in manner other than
shown.
EXAMPLE OF LOCATION TO REDUCE THE RISK OF FIRE
1.5 m (5 ft.)
Direct exhaust AWAY from
windows, doors,
1.5 m (5 ft.) min
min.
and
vents.
.
11

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

030648

Tabla de contenido