0Man136 Man.Solo Foster 05-2001.qxd
-
faulty condenser fan motor
GB
The device resets itself automatically when the windings cool down.
I
2) Formation of ice on evaporator coil impeding regular air flow. Possible causes
are:
-
excessive door openings/door left open for long periods
F
-
faulty running of evaporator fans
-
faulty by pass solenoid valve
D
-
pre set defrost routine not sufficient to effect full defrost. In this case it is pos
sible to make some modifications:
-
increase the defrost termination temperature by a few degrees
E
-
decrease the time interval between defrosts ( i.e increase no. of defrosts ) -
modifications to be made by your installer.
3) Display does not light. Check:
-
there is power to the unit
-
correct connection of mains cable
-
fuses inside electrical panel
4) If display lights but when ON/OFF key is pressed ( for 3 seconds ) unit does not
turn ON: check correct connection of the door micro switch remembering that
the switch contact must be closed when door is closed.
8 8
. .
R R
O O
U U
T T
I I
N N
8 8
. .
R R
O O
U U
T T
I I
N N
In order to keep the unit operating reliably and efficiently it is necessary to periodi-
cally clean the condenser. ( The frequency depending on the location in which
the unit is installed. ) This operation is to be done with the mains turned OFF. We
advise use of an air jet blowing from the inside towards the outside. If an air jet
is not available then use a soft long haired brush on the outside of the conden-
ser taking care not to damage the condenser fins. WARNING condenser fins
have sharp edges.
9 9
. .
W W
A A
R R
N N
I I
N N
9 9
. .
W W
A A
R R
N N
I I
N N
Installation and repair is to be carried out by authorised personnel only.
Whenever it is necessary to make any maintenance operation to the unit it is a must to:
a) Stop the unit by pressing the ON/OFF key.
b) Remove power to the unit by turning off the mains magneto-thermic isolator which
has to be fitted to the units' power supply.
Whenever removing the units' cover be careful of the pipes which can be very hot or
very cold.
All refrigerants must be re-claimed and not vented to the atmosphere. Only charge unit
with the same refrigerant as indicates on the serial no. plate.
07/04/03
16.26
E E
M M
A A
I I
N N
T T
E E
N N
A A
N N
C C
E E
M M
A A
I I
N N
T T
E E
N N
A A
N N
C C
G G
S S
G G
S S
n°10
Pagina
10
E E
E E

Publicidad

Tabla de contenido
loading

Productos relacionados para Foster SOLO

Tabla de contenido