STEP 3: Connect Grounding Wire
A grounding wire
is recommended to protect
4
your device from lightning strikes and the
buildup of static electricity.
A grounding Wire is not included in the package.
4
It is suggested that you use 16 to 18 AWG
grounding wire.
STEP 4: Connect the AP to Your Network
PoE Injector
P+DATA OUT
C
DATA IN
B
Router or Switch
POWER IN
A. Connect the Ethernet cable (connected
to the AP in STEP 1) from the AP to the
"P+DATA OUT" port on the PoE Injector.
B. Connect an Ethernet cable from a router/
switch or PC to the "DATA IN" port on the
PoE Injector.
C. Attach the power adapter to the connector
labeled "POWER IN" on the PoE Injector,
and attach it into an electrical outlet.
AP
A
LAN (PoE)
Computer

Configuration

If you are configuring the AP locally, connect a
PC to the PoE Injector "DATA IN" port using an
Ethernet cable.
A. Assign a static IP address to your PC which
is in the same network segment with the
device. As the default IP address of this
unit is 192.168.0.50, you may choose any
address from 192.168.0.1 to 192.168.0.254,
except 192.168.0.50.
B. Open
a
web
http://192.168.0.50. Enter admin as your
username and leave the password blank to
log into the web UI. Now you can configure
the AP via web UI.
D-Link DAP-3310/DAP-3410 Quick Install Guide  3
browser
and
go
to

Publicidad