CLEANING PROCEDURE
Switch off the device and unplug the power cable from the socket before all maintenance
• •
work and after each use.
Never submerge the device in water (this can result in short-circuiting/ electric shock). To
• •
clean the device, simply wipe it with a damp cloth and then dry it thoroughly. Always ensure
the power cable has been unplugged beforehand.
The cover (18) and air filter (17) on the reverse can be removed to enable easier cleaning:
• •
Remove cover: pull down one of the side opening flaps (19) and remove the cover (18).
• •
Remove air filter: unhook one of the two side mounting brackets (16) by pressing it in gently.
• •
Then remove the filter by pulling backwards.
Remove fluff with a brush or vacuum with a brush attachment. Do not press on the filter (it may
• •
tear). Clean any plastic components with a damp cloth.
Re-insert the components in reverse order: re-attach the filter to the case using the mounting
• •
bracket. Gently press the flap on the other side in the middle so that it can be attached to
the case (should snap into place). Attach the cover to the device from the back until all four
fastening tabs have snapped into place (do not use force; cover may be upside down and
therefore may not fit). Never use the device without a filter or cover!
Empty the water tank daily.
• •
Wash the inside of the tank with warm water and a normal detergent at least once a month for
• •
hygiene reasons. First, remove the white tank lid (22) (hold the front edge of the lid, swivel up
slightly and then pull away from yourself).
Do not place the tank or lid in a dishwasher or clean with an abrasive agent otherwise the parts
• •
may become damaged.
STORAGE
Unplug when not using the device for a long period of time (e.g. while on holiday). Empty the
• •
water tank and leave to dry along with the device for 1-2 days (to enable condensation inside
to evaporate and ensure that the device is completely dry). Then store the device in a dry and
dust-free location.
Tip: Retain the packaging to store the device.
• •
18
TECHNICAL DATA
Dimensions
Weight
Voltage
Output
Suitable for room size
Dehumidification capacity
Automatic switch-on/off
Tank capacity
Fulfils EU regulations
Subject to technical changes and errors without notice.
TROUBLE-SHOOTING
«Water Full» lit up
Water tank is full; empty tank à page 17.
«Water Full» light on
Water tank is not properly in place à slide tank in fully (must snap into place and sit flush with the
sides).
Compressor protective circuit is still active. It can take 3 minutes for the compressor to switch
back on (and for the display to turn off).
Device off and none of the buttons working
The room temperature is too low (below 0 °C) or too high (over 40 °C) à page 17. If the device
does not react after warming or cooling of the room, remove the plug for a few seconds and then
re-insert (= «Reset»).
«DEFROST» lit up and compressor not working
Device needs to be defrosted à page 17.
Water tank leaking
Water droplets can escape when the tank is inserted/removed. However if the tank actually is
leaking, it will need to be replaced. Never drop the tank or place it in a dishwasher because it may
become damaged.
347 x 495 x 247 mm (width x height x depth)
10.2 kg
220-240 V / 50/60 Hz
255 W
40m² or 100m³
max. 12 l / day
yes/yes
2 l / 0.528 US gallons
CE/WEEE/RoHS