selected using the BOOST function.
The time remaining will scroll across the display until the end of the preset
period. Press the Boost button to exit the BOOST function.
will flash to indicate that the BOOSTPROg function is active. To disable this
function, press the
button to go to NO-heAT.
NOTe: The BOOSTPROg function will be deactivated if the power supply is
interrupted.
3.5 Programme function (Auto mode)
OPeRATION WITh A PIlOT WIRe PROgRAMMINg BASe UNIT
Your appliance can be controlled remotely by a Pilot Wire programming base
unit. Once connected (see section 2.3), the appliance will recognise the programming
base unit automatically.
OPeRATION WITh A PlC PROgRAMMINg BASe UNIT,
PlC ASSOCIATION/dISSOCIATION
Your appliance can be controlled remotely by a
PLC (Powerline Carrier) programming base unit using
the X2D protocol. To use this facility, remove the cover
and insert the Powerline Carrier interface module (op-
tion, please contact your installer or dealer) in its place.
Regardless of what the display is showing,press the Boost and + buttons for
10 seconds.
will then be displayed and flashing: your appliance is waiting to receive an
association signal from a PLC unit (to activate the association signal, see the instruc-
tions supplied with the unit). Run the association procedure on the control unit, then
press once on the Boost button.
will then be displayed permanently: your appliance is now associated with
this transmitter unit. To quit this procedure, press the Boost and + buttons.
If the device does not find a PLC signal, it will automatically quit the association
mode after 2 minutes.
To dissociate your appliance from this PLC unit, press the Boost and + button
for 10 seconds, regardless of what the display is showing.
will flash. Press the Boost button for 20 seconds until the light flashes fast,
then release it. In AUTO mode
PLC unit
30
Insert module
Cover
(option)
appears: your appliance is now dissociated from this
NOTe: The PLC programming base unit must not be emitting any signal during
the dissociation process.
NOTe: The association process must be repeated each time the module is
changed.
3.6 electronic lock
Use of this function prevents any unwanted operation of the keypad.
Press the + and – buttons together for 5 seconds to lock the keypad and prevent
any inadvertent change of mode or setpoint temperature.
The
symbol will then appear.
To unlock, press the + and – buttons together for 5 seconds. The symbol
sappears.
NOTe: This function will not block mode change commands from a Pilot Wire or
PLC unit.
3.7 Calibrating and dissociating the Comfort and eco
temperatures
The calibration facility can be used to correct any variation between the room
temperature achieved by the appliance and the setpoint temperature requested at the
thermostat.
To do this, enter the variation between the temperature measured by a thermo-
meter in the room and the temperature achieved in COMfORT mode.
Hold the Boost and – buttons on for 5 seconds. The screen shows "0".
The thermostat will then allow the measured temperature reading to be chan-
ged by up to + or - 5°C in 0.5°C increments by pressing the + and – buttons.
Then press the Boost button to switch to eCO mode temperature association/
dissociation.
Press the + and – buttons to select:
- Of: The eCO mode temperature is your chosen comfort mode temperature
minus 3.5°C.
- ON: The eCO mode temperature can be set independently of the COMfORT
mode temperature. In eCO mode, you can now press the + and – buttons to increase
or reduce the temperature in 0.5°C steps.
Press the Boost button to exit.
40005939
40005939
EN
di-
31