3.2. POWER SOURCE. OPERATION CONTROLS.
The INDUSTRIAL GALA equipment control panels are given in figure 8. The operations carried out by the
controls are described below:
N- GENERAL ON/OFF SWITCH.
With this switch we can start up the power source.
P- DIGITAL VOLTMETER.
It measures the voltage of the welding circuit. (Optional for GALA MIG 3007)
Q- DIGITAL AMMETER.
It measures the intensity of the welding circuit. (Optional for GALA MIG 3007)
R- ON-OFF INDICATOR.
Equipment ON/OFF indicator light. It must stay ON when activating control N. If not, fuse T could have
"BLOWN", fault in the mains, etc.
T- FUSE-HOLDER.
Control circuit protection fuse system.
U- INCREMENTAL TAP CHARGER.
This enables the correct welding voltage to be selected within the chosen range. It has 10 selection levels,
which will permit the best adjustment for each specific job.
V- SCALE SWITCH.
The variation of the welding voltage is divided into two ranges for the GALA MIG 3007 and into three
ranges for the GALA MIG 4007.
GALA INDUSTRIAL.. Instructions Manual.
Figure 8 - Control panels of the INDUSTRIAL GALA equipment.
R
24