1. Remove the four Phillips-head screws from
the front of the module and lift the module
from the turbine.
2. To change terminal block connections, loosen
the appropriate screws. Reconnect the wires
in the proper positions and tighten the screws.
3. Install the batteries. Make sure the positive
post is in the correct position.
4. Position the module on the turbine housing.
To avoid moisture damage, make sure the
seal is fully seated. Tighten the four screws
on the front of the module.
Ten feet (3 m) of cable is provided with the mod-
ule. Trim the cable to desired length or extend
it as necessary.
Verify Meter Accuracy
Before using, check the meter's accuracy and
verify calibration.
1. Make sure there is no air in the system by
starting the flow until it runs steadily. Then,
stop or divert the flow using a valve or nozzle.
2. Meter an exact known volume into an ac-
curate container. For best results, meter with
one continuous full stream.
3. Check the volume against the display or
recording equipment. If the amount metered
is accurate, further calibration is not neces-
sary. If not, refer to the Calibration Section
for further instructions.
OPERATION
Computer Display –
Batch and Cumulative Totals
The computer maintains two totals. The Cumula-
tive Total provides continuous measurement and
cannot be manually reset. The Batch Total can
be reset to measure flow during a single use. The
Cumulative Total is labeled with TOTAL 1, Batch
Total is labeled TOTAL 2 BATCH.
When the Cumulative Total reaches a display
reading of 999,999 the computer will highlight
an X10 icon. This indicates to the operator that
a zero must be added to the 6 digits shown.
When the next rollover occurs, the computer
will highlight an X100 icon. This indicates to the
operator that two zeroes must be added to the
6 digits shown.
4
Press the DISPLAY button briefly to switch
between the TOTAL 1, TOTAL 2 BATCH and
FLOWRATE. Press DISPLAY briefly to display
the TOTAL 2 BATCH. Hold the DISPLAY button
for 3 seconds to reset the Batch Total to zero.
When fluid is flowing through the meter, a small
propeller icon is highlighted.
NOTE: Totalization counts total units without
differentiating between gallons, litres or field
calibrated units.
Flowrate Feature
To use this feature, press and release DISPLAY
until FLOWRATE icon appears. The factory
set time base will be highlighted to the right of
FLOWRATE (M = minutes, H = hours, D = days).
When FLOWRATE is invoked, the display will be
indicating rate of flow.
Activate the Meter
Computer is on continuously and always ready
to perform. The computer is powered by field
replaceable batteries. When display becomes
dim, faded or the low battery message appears
(see below), the batteries need to be replaced.
Reference the Maintenance Section for details.
Factory and Field Calibration
All calibration information is visible to the user
as icons on the top line of the display, above the
numeric digits.
All units are configured with a "factory" calibra-
tion. Both gallons and litres are available ("GL"
or "LT" will be displayed). While holding the
CALIBRATE button, briefly press DISPLAY to
toggle between gallons and litres. This factory
calibration (indicated with FAC) is permanently
programmed into the computer and is not user
adjustable.
NOTE: Your computer may have other units of
measure programmed into it. If so, holding the
CALIBRATE button and momentarily pressing
the DISPLAY button will toggle through all
factory set units. Other possible units are:
IGL (imperial gallon), QT (quart), CF (cubic
feet), CM (cubic meter), BL (42 gal. barrel),
CC (cubic centimeter) or OZ (ounce).