MAINTENANCE / RECOMMENDATIONS

Ensure the machine is unplugged from the mains, and then wait 2 minutes before carrying out maintenance work. Inside,
voltages and currents are high and dangerous.
Maintenance should only be carried out by a qualified person. A yearly maintenance is recommended.
1 - Air filter maintenance :
• It is necessary to periodically purge the air filter. To do so, press and hold the orange button below the filter .
• Disassembly :
- Unplug the air supply.
- Grab the tank, press the latch and rotate the tank 45 degrees to the left.
- Pull the cube downwards and then put it down.
- The filtering part is white, clean or replace it if necessary (ref. 039735).
2 - Periodical maintenance:
• Periodically remove the cover and dust with an air gun. Take this opportunity to have the electrical connections checked by a qualified person, with
an insulated tool.
• Regularly check the condition of the power supply cable. If the power cable is damaged, it must be replaced by the manufacturer, its after sales
service or an equally qualified person to prevent danger.
• Do not obstruct the machine's air intakes for a good air circulation.
• Check that the torch does not have any cracks or exposed wires.
• Check that the consumables are installed properly and not worn.
INSTALLATION – PRODUCT OPERATION
Only qualified personnel authorised by the manufacturer should perform the installation of the welding equipment. During the installation, the
operator must ensure that the machine is disconnected from the mains.
MACHINE SUPPLIED WITH
MACHINE DESCRIPTION (FIG. 1)
70T Cutter is a cutting & three-phases Plasma gouging root, it allows :
- Cutting on all metal types
- Gouging on all metal types
These two processes require the use of appropriate consumables and compressed air.
1-
Man to Machine Interface
2-
Plasma torch connector
3-
Pressure adjustment knob.
4-
Earth clamp connection socket
5-
Transport handles
INTERFACE (MMI) (FIG-2)
1-
Thermal protection indicator
2-
Indicator «Stop caused by intervention on the torch»
3-
Malfunction (machine is not functioning normally) indicator
4-
Full sheet cutting indicator
5-
Selection mode button
6-
Full sheet cutting indicator with lock trigger for longer cuts
16
CUTTER 70 CT
6 m
4 m - 10 mm²
Starting kit
Pneumatic fittings
Accessories supplied with the generator are designed to be used on this machine only.
CUTTER 70 CT
Ref. 013636
Ref. 013841
-
-
8 mm + 10 mm
8 mm + 10 mm
6-
Power supply cable
7-
Filter
8-
On/off switch
9-
Replacement for pneumatic connector
10-
Installation door for CNC kit (optionnal, ref. 039988)
7-
Full sheet cutting indicator with the pilot-arc restart
8-
Current setting potentiometer.
9-
Bar-graph Pressure indicator
10-
Indicator «insufficient pressure»
11-
Test and adjustment button for Air pressure
12-
Indicator of air running test