GYS EASYCUT 40 Manual De Instrucciones página 15

Cortador al plasma monofásico
Ocultar thumbs Ver también para EASYCUT 40:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
MAINTENANCE / RECOMMENDATIONS
Ensure the machine is unplugged from the mains, and wait for two minutes before carrying out maintenance work. DANGER High
Voltage and Currents inside the machine.
Maintenance should only be carried out by a qualified person. Annual maintenance is recommended.
1 - Air filter maintenance:
• It is necessary to periodically empty the air filter. To do so, press and hold the orange button below the filter.
• Disassembly:
- Unplug the air supply.
- Grab the tank, press the latch and rotate the bowl 45 degrees to the left.
- Pull the cube downwards and then put it down .
- The filtering part is white, clean or replace it if necessary (ref. 039735).
2 - Periodical maintenance:
• Periodically remove the cover and dust with an air gun. You are advised to have the electrical connections checked by a qualified person, with an
insulated tool.
• Regularly check the condition of the power supply cable. If the power cable is damaged, it must be replaced by the manufacturer, an after sales
service or a qualified person to prevent danger.
• Do not obstruct the machine's air intake, to allow air circulation.
• Check that the torch does not have any cracks or exposed wires.
• Check that the consumables are installed properly and not worn.
• Do not use this equipment to thaw pipes, to charge batteries, or to start any engine.
INSTALLATION – PRODUCT OPERATION
Only qualified personnel authorized by the manufacturer should perform the installation of the cutting equipment. During set up, the operator must
ensure that the machine is unplugged. Connecting generators in a series or a parallel circuit is forbidden. It is recommended to use the welding cables
supplied with the unit in order to obtain the optimum product settings.
MACHINE SUPPLIED WITH
The accessories supplies with the machine are to be used only with the same models.
HARDWARE DESCRIPTION (FIG-1)
1-
Keyboard + buttons
2-
Torch connector
3-
Earth clamp connector
4-
Compressed air connector
CONTROL BOARD (IHM) (FIG-2)
1-
Power indicator (green)
2-
Thermal protection and over current protection indicator (yellow)
3-
Torch and air pressure fault light
4-
Cutting current adjustment
POWER SUPPLY – STARTING UP
This machine is fitted with a 16A socket type CEE7/7 which must be connected to a single-phase 230V (50 - 60 Hz) power supply fitted with three
wires and one earthed neutral. The absorbed effective current (I1eff) is indicated on the machine, for optimal use. Check that the power supply and
its protection (fuse and/or circuit breaker) are compatible with the current required to run the machine (l1max). Use preferably a 32A plug with a 32A
circuit-breaker for intensive use. Position the device so that the socket is always accessible.
They are power supplied by a 230V +/- 15% (50 - 60 Hz) EARTHED installation and are protected to work with generators. This hardware must only
be used with a one phase electricity supply protected by a earthing wire.
The absorbed effective current (I1eff) is displayed on the machine, for optimal use. Check that the power supply and its protection (fuse and/or circuit
breaker) are compatible with the current needed by the machine.
EASYCUT 40
EASYCUT 40
Ref. 029743
TPT 40
4 m
2 m - 10 mm²
-
Starting kit
8 mm
Pneumatic fittings
5-
Air filter
6-
On/off switch
7-
Power supply cable
8-
Air regulator (air pressure adjustment)
5-
Selection button (air pressure or cutting mode)
6-
Air pressure selection indicator
7-
Starting the cutting mode indicator
8-
Indication to measured pressure value (LED).
EN
15

Publicidad

Tabla de contenido
loading

Tabla de contenido