INSTALLATION MANUAL
KCIN
Illuminated weatherproof Keypad with Remote Electronics
and faster to change its code.
1. Enter the master code twice
(1 2 3 4 5 default value master code).
2 beeps are emitted to confirm entry
in programming mode.
2. Press A7 to program a sub master
code for the user individual Pin
code modification.
One beep is emitted. Enter the new
2-digit sub master code. One beep
is emitted to confirm programming
of the sub master code.
3. Press B to exit from
the programming mode.
2 beeps are emitted to confirm
that the keypad is in stand-by
operating mode.
I. Audible Feedback
The audible signal is enabled
in programming mode
and when the relay is energised
after a valid code.
To enable the audible feedback
on a key press:
1. Enter the master code twice
(1 2 3 4 5 default value master code).
2 beeps are emitted to confirm entry
in programming mode.
2. Press AA.
One beep is emitted. Press 0 to disable
the audible signal during a keypress.
Press 1 to enable the audible signal
during a keypress. One beep confirms
the new setting.
3. Press B to exit from programming.
2 beeps are emitted to confirm exit
from programming mode.
14
14
cdvigroup.com
J. OPTIONAL KCIN 2 AND KCIN 3
PROGRAMMING INSTRUCTION
Programming instructions are the same
as for the KCIN keypad with 1
relay output.
KCIN 2: 2 relay outputs N/O
and N/C contacts 8A @ 250V~.
Group 1: From user location 00
to user location 59 to activate relay 1.
Group 2: from user location 60
to user location 99 to activate relay 2
Release Time of relay2 enter A2,
sub master code enter A8
(default values 1 and 3).
KCIN 3: 3 relay outputs N/O
and N/C contacts 8A @ 250V~.
Group 1: from user location 00
to user location 59 to activate relay 1.
Group 2: from user location 60
to user location 79 to activate relay 2.
Group 3: from user location 80
to user location 99 to activate relay 3.
Release time for relay 3 enter A3
sub master code enter A9
(default values 4 and 6).