Start And Stop; Operating; Maintenance; Every Day - Chicago Pneumatic CP 0077 Instrucciones De Seguridad Y De Funcionamiento

Bomba para lodos
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 46
Safety and operating instructions

Start and stop

WARNING
Whipping discharge hose
A discharge hose that comes loose can lash around,
and the hose or jets of liquid can hit the operator,
and cause personal injury or death. To reduce this
risk:
Always remove kinks, before the pump is started.
If the discharge hose is kinked, it can be forced
out of the operator's hands.
Always make sure that the discharge hose
connections are properly attached.
Check that the discharge hose and the
connections are not damaged, replace if
necessary.
Always make sure that the outlet end of the
discharge hose is properly secured.
Start and stop
Start the pump by connecting it to the power
source.
Stop the pump by disconnecting it from the
power source.

Operating

>
The following must be performed at the start of
every shift:
>
Shut off the compressed air.
>
Fill the oiler with oil.
>
Check that the oil dosage is functioning, by
holding a piece of clean paper in front of the
exhaust air outlet. After about five pump
strokes, traces of oil should appear on the
paper.
>
Adjust the oil dosage if necessary, see section
("Oiler adjustment").
>
Allowing liquid to freeze inside the pump can
cause damage to the pump.
>
The pump can be run dry, but doing so will
increase the air consumption.
>
If the pump has been used in corrosive or polluted
water, it must be operated in clean water for a
few minutes after use.
>
If the pump operates but discharges little fluid,
inspect inlet check valve and clean out any foreign
objects which may be holding check valve open.
12
www.CrowderSupply.com • Toll Free: 888-883-5144

Maintenance

Regular maintenance is a basic requirement for the
continued safe and efficient use of the machine.
Follow the maintenance instructions carefully.
Use only authorised parts. Any damage or
malfunction caused by the use of unauthorised
parts is not covered by warranty or product
liability.
When cleaning mechanical parts with solvent,
comply with appropriate health and safety
regulations and ensure there is satisfactory
ventilation.
For major service to the machine, contact your
nearest authorised workshop.

Every day

Before undertaking any maintenance on the pump,
always switch off the air supply. Then disconnect
the air hose from the machine.
Clean and inspect the machine and its functions
each day before the work commences.
Conduct a general inspection for leaks and
damage.
Check that the air inlet nipple is tightened and
that the claw coupling is free from damage.
Change damaged parts immediately.
Replace damaged and worn components in good
time.
Make sure that all the attached and related
equipment, such as hoses, water separators, and
lubricators are properly maintained.

Periodic maintenance

Since each application differs, the frequency and
extent of maintenance is best established based upon
past performance. Keeping detailed maintenance
records of past performance, aids determining future
preventative maintenance intervals.
9800 0556 90a | Original instructions
CP 0077

Publicidad

Tabla de contenido
loading

Tabla de contenido