Tightening Torques - Chicago Pneumatic CP 0077 Instrucciones De Seguridad Y De Funcionamiento

Bomba para lodos
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 46
CP 0077
Periodic maintenance
Time interval, pump hour
Check
Check
Every
point
concerns
Hoses and
Leakage,
connections
damage
Threaded
Tightness
unions
Pump,
-
complete
Oiler
Oil level,
function
Ejector
Fill with 8
valve
drops of oil
Control
Greased
valve
*If the pumped medium is very abrasive, the time
interval should be reduced to 400 hours.
The control valve must be greased with a good grade
of grease containing graphite.
In the event of breakdown or worsening pump
performance, establish the cause and rectify the fault.
Ideally, repairs should be carried out in an authorised
workshop.
9800 0556 90a | Original instructions
Every
Every
8th
40th
800th*
X
www.CrowderSupply.com • Toll Free: 888-883-5144
X
X
X
X
X
Safety and operating instructions

Tightening torques

A.
Cap screw, 11.0-14.8 lbf/ft (15-20) Nm
Nipple and Body for oiler, 22.1-29.5 lbf/ft
B.
(30-40) Nm
C.
Check valve nut, 11.0-12.5 lbf/ft (15-17) Nm
D.
Nut, 22.9-25.1 lbf/ft (31-34) Nm
13

Publicidad

Tabla de contenido
loading

Tabla de contenido