3 Installation
3.5.1 Setting of the switch-off limit for low
battery voltage (F1)
In this setting the voltage value is set at which the parking
cooler is automatically switched off as soon as the value is
dropped below.
•
Setting range: 20.1 to 25.0 V.
•
Factory setting: 23.5 V.
1. Call setting F1.
2. To change the value, press the Fan + or Fan –
button on the control panel.
3. Confirm the desired value by pressing the Timer
button on the control panel.
CAUTION
If the parking cooler is switched off due to low
battery voltage, the battery must be recharged
as soon as possible. If the battery continues to
be discharged, the battery voltage may not be
sufficient to start the engine.
16
3.5.2 Setting of the switch-on limit for low
battery voltage (F2)
In this setting the voltage value is set at which the parking
cooler can be switched on again (after an automatic switch-
off due to low battery voltage has taken place).
•
The switch-on voltage must be at least 1.5 V over
the switch-off voltage.
•
Setting range: 21.6 to 26.5 V.
•
Factory setting: 25 V.
1. Call setting F2.
2. To change the value, press the Fan + or Fan –
button on the control panel.
3. Confirm the desired value by pressing the Timer
button on the control panel.
3.5.3 Setting of the minimum display
brightness (F3)
The display brightness is automatically adjusted to the
ambient brightness. The minimum display brightness can be
set.
•
Setting range: six levels, however not greater
than the maximum brightness (F4).
•
Factory setting: Level 2.
1. Call setting F3.
2. To change the value, press the Fan + or Fan –
button on the control panel.
3. Confirm the desired value by pressing the Timer
button on the control panel.
3.5.4 Setting of the maximum display
brightness (F4)
The display brightness is automatically adjusted to the
ambient brightness. The maximum display brightness can be
set.
•
Setting range: six levels, however not less than
the minimum brightness (F3).
•
Factory setting: Level 6.
Cool Top Vario 10 E