Replacing the Fuse
1.
Disconnect this product from power.
2.
Using a flat-head screwdriver, unscrew the fuse holder cap from the housing.
3.
Remove blown fuse and replace with a good fuse of the same type and rating.
4.
Screw the fuse holder cap back in place and reconnect power.
DMX Linking
The Ovation P-56FC will work with a DMX controller using a 3- or 5-pin DMX data connection. A DMX Primer is available
from www.chauvetprofessional.com.
DMX Connection
The Ovation P-56FC uses a 3- or 5-pin DMX data connection for its 9 DMX personalities: 1 Ch, 3 Ch, 5 Ch, 7 Ch, 10 Ch,
12 Ch, 13 Ch, 15 Ch, and HSV. See the User Manual for information about connecting and configuring the product for
DMX operation.
Master/Slave Connection
The Ovation P-56FC uses the DMX data connection for its Master/Slave mode. See the User Manual for information
about connect and configure the product for master/slave operation.
RDM (Remote Device Management)
Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate bi-directionally
along existing DMX cabling. Check the DMX controller's User Manual or with the manufacturer as not all DMX controllers
have this capability. The Ovation P-56FC supports RDM protocol that allows feedback to make changes to menu map
options. Download the User Manual from
Alternate Lenses
The interchangeable Medium and Wide lenses allow the product to have alternate beam angles.
Pull knob up to
release and
change the lens
Mounting
Before mounting this product, read the
mounting clamps are capable of supporting the weight of the product. For our Chauvet line of mounting clamps, go to
http://trusst.com/productcategory/truss-clamps/.
Product Mounting Diagram
Overhead Mounting
Ovation P-56FC QRG Rev. 5
QUICK REFERENCE GUIDE
www.chauvetprofessional.com
Safety
Notes. Use at least one mounting point per product. Make sure the
Mounting Clamp
Safety Cable
for more details.
Floor Mounting
EN
2