MSG-150.book Seite 21 Donnerstag, 30. Oktober 2008 5:03 17
MagicSafe MSG150
6
Technical description
The MSG-150 gas detector can be used as a warning device in many areas to detect
gases with a narcotic effect before they can take effect.
MSG-150 contains a sensor and an acoustic signal generator and is connected to a 12/24
V DC voltage supply, e.g. the cigarette lighter in a vehicle.
In addition to this, MSG-150 contains an internal relay. An external siren of signal lamp
can be connected to this.
The connection terminal for the relay connection can be found on the back of the gas
detector (3, page 4).
No. in
Description
3, page 4
1
Relay contact 1
2
Relay contact 2
You can operate MSG-150 in three ways:
As single device
In combination with the MS-620SI external siren
In combination with MagicSafe MS-650 or MS-620 alarm systems
7
Mounting the gas detector
7.1
Tools required
For mounting you will require the following tools:
Measuring ruler (1 1, page 3)
Centre punch (1 2, page 3)
Hammer (1 3, page 3)
Drill bit set (1 4, page 3)
Drill (1 5, page 3)
Screwdriver (1 6, page 3)
Technical description
21