CHANGING RELAY SETTINGS
By default:
•
The relay activated when a valid access code
is recognised is the SE output on the audio or
audio/video module
•
the codes are set as permanent
If the number keypad module is in stand-alone
mode, or if you want to change these parameters,
you will need to follow the procedure below:
1.
For the default setting, enter the first 5
characters of the supercode
» the LED
lights up in yellow
2.
Enter B5
3.
Enter the number corresponding to
the output you wish to activate
1 = keypad relay 1
2 = keypad relay 2
3 = keypad relay 1 and relay 2
4 = audio or audio/video module SE
output (default)
5 = audio or audio/video module relay 1
6 = SBC or VIP external actuator
4.
If you chose "6 = SBC or VIP external
actuator" in point 2, enter the actuator
address, otherwise press 0
5.
Set the opening code validity
0 = permanent, the access code is
always valid (default)
N [1 – 9] = limits the number of times the
code can be entered (e.g..: if you select
"5" the code can be used 5 times before
it is deleted)
6.
Press
twice to exit programming
mode
CAUTION: From this moment all the new access
codes saved will activate the configured output
and will have the new validity set. Previously
saved access codes remain unchanged.
PERMANENT ACTIVATION OF THE NUMBER
KEYPAD MODULE BACKLIGHT IN STAND-ALONE
MODE
1.
For the default setting, enter the first 5
characters of the supercode
» the LED
lights up in yellow
2.
Enter the code B0
3.
Enter the programming sequence
4.
Press
twice to exit programming
mode
The keypad has several advanced functions as
described in the full manual, which is available to
download from the website pro.comelitgroup.com
Programming via ViP Manager
The ViP Manager software used to program the
number keypad module using a computer is available
on the website pro.comelitgroup.com.
The main functions available are as follows:
•
Access code entry. The access codes may be
Permanent (always valid), metered (valid for a certain
number of uses) or associated with a validity date. In the
latter case, each code can be assigned a validity start/
77889
end date, dual daily time band and validity days.
•
Each access code can be assigned up to 4 different
actions which will be carried out consecutively.
•
Call code entry. The call function is enabled by default.
It can be disabled.
•
Activation of playback of the relevant audio message
when each button is pressed (e.g. if you press 2 on the
(number)
number keypad, audio message "two" will be played).
•
Event log complete with all information (activated codes,
user that used them, users called, etc.). Up to 1275
events can be saved in the memory.
•
"Trade" function. On specific days of the week and in
specific time bands, simply press the key button (without
entering a code) to activate keypad relay 1 without an
external clock.
(address)
CONNECTIONS AVAILABLE FOR PROGRAMMING
VIA VIP MANAGER
(number of
uses)
1210
1210A
2 ×
1595
1440+1441
Search for devices to configure (fig. page 40)
√ Connect the number keypad to the computer
and open ViP Manager
In Options (1)/Local connections (2), select the
network interface (3).
Confirm by clicking OK (4).
77889
Click Scan system (5) to start searching for devices.
Populating the directory (figure page 40)
1.
Select Directory/Directory
520330090
2.
Enter the information required (for each contact
you need to enter at least one "access code";
enter the "Name" if you want to pair actions)
2 ×
3.
Press "Write page" to send the data to the
number keypad module
19