a
It is recommended that you test the stove before constructing the lining wall and installing the surround.
a
Under no circumstances fix the stove, to allow normal expansion during operation.
Scrupulously follow the installation instructions and comply with the measurements given in the picture and those given in the stove instruction
booklet.
To ensure the structure is safely anchored, when erecting the plasterboard wall it is a good rule to use studs (minimum width 5 cm) at the points
where the surround will be fixed to the wall.
a
It is advisable to insulate well using standard materials, thickness and distances in accordance with indications given in the stove
instruction booklet.
a
The recommended distances are the minimum for proper installation on non-flammable walls.
With flammable walls, follow the instructions given in the stove operating and maintenance booklet under "MINIMUM SAFETY
DISTANCES".
Model
A
B
IP 68/49
55
129
SCP 7
IP 78/58
61
144
SCP 9
IP 78/68
61
144
(1) The measurement H defines the height of the below base to the ground.
(2) Measurements tied to H.
(3) Version with Pellet Drawer Kit (optional).
a
It is possible to change the hight of the frame from the ground adding or subtracting to the values "H", "L" and "N" the required
difference.
2.2 FITTINg ThE EDgE TRIM
Check that the stove is working properly and upon completing the lining
wall as described in the paragraph "LINING WALL CONSTRUCTION",
proceed as follows:
a
Never fix any parts of the surround or lining wall directly to
the stove.
a
It is very important to check that the lining wall is perfectly
vertical and flat.
Position the edge trim and check that it is central in relation to the stove
and the aperture in the lining wall. If necessary use the fibreglass tape
provided in the kit to shim the edge trim to adjust the height.
a
Place the edge trim so that the flanged edge (A) is at the top,
as shown in the detail of figure.
Remove the edge trim. Paint and finish the lining wall.
Put a few spots of silicone on the edge trim and fix it to the lining wall.
a
Take care over how much silicone you use so that it does not
leak from the outer edge of the trim.
NON FLAMMABLE walls
C
D
E
F
91
5
5
5
102
5
5
5
102
5
5
5
H07028770 / DT2001014 – 02
F
H
I
P
(1)
50.7
78
38
1
56.7
(3)
59.7
88
38
1
65.7
(3)
69.7
88
38
1
75.7
(3)
Flue outlet
O
L
Ø
M
(2)
71
37.8
8
45
81
37.8
8
51.5
81
37.8
8
51.5
A
Height
N
(2)
68
cm
69.5
cm
69.5
cm
DT2011347-00
DT2031914-00
9