CONTROL PANEL
h
g
POWER
a
DISPLAY
Displays the current room humidity as a percent, or the
hours remaining in a Time Delay. The corresponding indicator
light will illuminate.
BUTTONS AND INDICATORS
A POWER BUTTON
•
Press the Power button to turn On/Off the
dehumidifier.
NOTE: Turning off power by pressing the Power
button does NOT disconnect the appliance from the
power supply.
B FAN SPEED BUTTON
The fan speed can be adjusted from Low to High speed.
•
Press the Fan Speed button to toggle among the two
speeds. The corresponding fan speed indicator will
illuminate.
C TIMER BUTTON
Auto Turn ON/Auto Turn OFF
Program a time from (1-hour to 24-hours) for the
dehumidifier to turn Off or On. When a Time Delay is
programmed, the Timer ON indicator light will
illuminate.
While the dehumidifier is operating:
1.
Press the Timer button.
2.
Press the Up Arrow/Down Arrow buttons to select
the number of hours you want the dehumidifier to
continue to operate before turning Off.
NOTE: After displaying the time, the Display
will revert to showing the current humidity after
10 seconds have passed.
While the dehumidifier is off:
1.
Press the Timer button.
2.
Press the Up Arrow/Down Arrow buttons to select
the number of hours you want the dehumidifier to
remain off before turning On.
HIGH
BUCKET
ON
FULL
DEFROST
LOW
OFF
SPEED
TIMER
b
c
% RH
HUMIDITY / TIME
d
NOTE: After displaying the time, the Display
will revert to showing the current humidity after
10 seconds have passed.
To cancel the timer:
•
Press the Timer button once, the hours remaining
will flash, press the timer button again and the timer
will be cancelled.
D HUMIDITY/TIME (Up and Down Arrow) BUTTONS
Adjusts the Humidity or Hours in Time Delay.
To Set the Humidity Level:
The humidity can be set between 30% Relative Humidity
(RH) and 90% RH. The humidity can be adjusted in
increments of 5% by each press of a button.
•
Press the Up Arrow/Down Arrow buttons to select
the desired Relative Humidity (RH).
NOTE: After setting the humidity level, the
display will revert to the current humidity after
10 seconds have passed.
E FILTER RESET BUTTON
•
Press this button to reset the air filter timer and to
turn Off the Check Filter indicator.
F FILTER STATUS
After 250 hours of operation, the filter indicator light will
illuminate to remind you to clean the air filter. Clean the
air filter. See "Cleaning."
G BUCKET FULL
When the water collection bucket is full the indicator
illuminates to remind you to empty the bucket.
H DEFROST
When the room temperature is low, the dehumidifier
enters defrost mode and the indicator illuminates.
6
f
CHECK
FILTER
FILTER RESET
e