TECHNICALINFORMATION
Finished products / Chassis concerned : ICC20
Object / Improvement of the demodulated picture in L standard (France only)
Symptom / Problem observed :
Light horizontal band at the top of the picture, mainly visible on programme 5. (la 5 & Arte)
Cause :
AGC too time constant too fast.
Solution :
Replace metalised polyester capacitor in position CI028 (1µF) by 2.2µF 50V. (Part N° 13085600)
K
L
RR015
TR015
RR001
RR014
QR001
RR007
TR013
BR060
RR012
IR001
1
RR050
060
RR051
RR111
RR112
114
RT013
RT005 RT002
RT012
RT001
RR118
TT080
TT070
CT014
80
RX504
RX505
CX504
RX503
CX505
QI033
TX503
CT080
1
TX500
LX601
CX500
RX500
JX855
CX550
CX540
IRIS CODE :The code mentioned below must be used to report the failure in the warranty sheet. It is
proposed to make your report easier and more reliable.
Condition/
Symptom/
1
3
2
X
1
You do not need to write anything in the white boxes
J
H
RR020
IR007
IR004
TR020
1
1
IR003
IR002
CT002
RR082
CR323
RR318
CR322
IR300
IR006
RR100
RR101
RR310
RR315
LR300
CR321
CR312
FI025
CR301
CI028
1
RI025
CI007
RI026
CX530
FI007
CC003
1
IC001
Part Code Number
3
0
8
5
6
0
G
F
BA010
CA124
CA127
RR104
RR093
RR103
RR091
RR102
BA005
1
RR090
CA119
RA121
RH010
Qty
Position
0
0
1
C
I
E
D
IA002
CA171
RA117
BA012
CA116
1
RA120
LA151
TA130
RA151
DA130
RA138
CA151
CA153
BA001
TA135
CA042
1
CA041
CA046 CA045
DA141
RA140
DA140
DA135
RA135
CA152
LA150
1
IA101
DA091
DA093
CA082
CA084
CA083
LA061
LA071
CA074
Section
0
2
8
I
F
C
C
B
7
BA009
CA170
6
1
RA171
RA170
1
RA168
5
CA175
BA002
CA182
CA105
4
CA184
CA197
CA156
3
CA163
LA111
LA110
Repair
Fault
Code
Code
Y
A

Publicidad

Tabla de contenido
loading

Tabla de contenido