Chlorine Production Control; Low Salinity Indicators - Davey ProMatic Manual De Instalación Y De Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 68

5.3 Chlorine Production Control

The values in respect of the pure chlorine produced by the unit are given in the table overleaf.
"Pure Chlorine" Production (Normal Mode selected) according to the Position of the Control Button
Adjustment of
Production Control
ProMatic MPS 16
ProMatic MPS 24
ProMatic MPS 36
ProMatic MPS 50
The above production values assume that salinity is correct and that the Spring Mode selector is in the
'OFF' position (in the season = normal mode).
SPRING MODE
POSITION
With the Spring Mode selector in the 'ON' position (off season), reduce the above values by 15%.
PRINTEMPS
POSICIÓN
PRIMAVERA
POSIZIONE
PRIMAVERA
PRODUCTION %
To check that the control mechanism is working properly and when the cell is not producing ("STANDBY"
indicator on), simply switch the production control button to "MAX". Production should start up again (and the
ProMatic
"STANDBY" indicator will go out).
To stop the cell producing without stopping the actual unit, switch the "PRODUCTION CONTROL" button to
"MIN". You may need to do this when backwashing the filter.

5.4 Low Salinity Indicators

Our unit has been designed with a system that will protect the pool in the event of insufficient salt.
When salinity drops, cell wear increases. Although salt is not consumed when the unit is in operation, it is lost
as a result of backwashing the filter, rain, and water losses for whatever cause (except evaporation, which does
not cause any loss of salt).
If salinity drops to an excessively low level, the LED 2 indicator will change to red, in which case you will need to
put some more salt into your pool. We recommend 1 kg of salt per m
Adding salt will not adversely affect the unit in any way, as it is protected.
If no action is taken and the salinity level continues to fall, the second indicator, LED 1, will also change to red,
at which point you must add salt as a matter of urgency (again, about 1 kg of salt per m
A
3.2g
4.8g
7.2g/hour
10.0g/hour
1
OPERATION
2
MIN
PRODUCTION CONTROL
®
B
6.4g
9.6g
14.4g/hour
21.6g/hour
20.0g/hour
30.0g/hour
MAX
PRODUCTION
REGLAGE
REGULACIÓN
REGOLAZIONE
of water.
3
C
D
9.6g
12.8g
14.4g
19.2g
28.8g/hour
40.0g/hour
of water).
3
MAX
16.0g
24.0g
36.0g/hour
50.0g/hour
13

Publicidad

Tabla de contenido
loading

Productos relacionados para Davey ProMatic

Tabla de contenido