Step 8: Remove the wire
shield. Pull on the wire shield
handle to remove the entire
shield, and place the shield
safely on top of the element
feeder.
Step
9:
Rewind the spool
counterclockwise to take the
excess slack from the wire and
the paper.
Step 10: Take the wire off the
magnet and place it on the
empty carrier paper you
rewound in Step 9. Pull the wire
toward the rewind spool making
sure to take up all of the slack.
Ensure that the wire you are
placing back on the spool is
contained in the paper you are
rewinding and does not interfere
with the other rows of wire
See Section 9 B for more
details.
Step 11: Secure the wire using
a magnet as shown. Repeat
steps 6 and 9 until all the wire is
on the spool
Step 12: Secure the wire rows
on the spool at the end of the
nd
lose wire using the 2
magnet
strip, then move the first magnet
strip you placed as shown here.
Place the magnets across rows
of wire so that the loose end of
wire is secured to the wound
rows. The magnets prevents the
wire from slipping when the
spool is removed.
Step 13: Tear the carrier paper
where it leaves the rewind
spool. Your carrier paper should
extend about 12 inches (30 cm)
beyond the loose end of your
wire.
Step 14: Unscrew the spool
retainer.
counterclockwise to loosen and
remove the cap. Set the cap
aside.
Step 15: Remove the spool from
the machine. Pull the spool
straight away from the machine
to slide it off the spindle. Properly
store the spool for future use.
Refer
guidelines on spool storage.
Note that the flexible magnet
must remain in place at all times
to prevent slipping of wire.
Step 16: To remove the rewind
spool from the feed spindle, push
the hub in and turn it clockwise.
Remove the excess paper by
sliding it off the hub.
Note: If the rewind spool is full of
paper, it may be difficult to
remove. The spool must be
pressed in firmly before rotating
to disengage the pin.
Step 17: Reinstall the empty
paper feed hub to the machine.
Slide it onto the feed hub shaft
and rotate counter clockwise
until it latches in place.
Step 18: Open the top cover and
identify the wire Holder. Check if
there is a cut length of wire on the
Holder (long boxed section). If
there is, remove it by pressing
the Holder release (small boxed
sections) and removing the wire.
Step 19: If a new spool is to be
installed, follow the steps in the
section, Section 7 B.
Step 20: If no new spool is to be
installed, reinstall the element
shield and slide the feeder
drawer back into the machine
until it latches, and close the
access door panel.
8
Turn
the
knob
to
Section
4
C
for
eWire™
ro
GB