6 TROUBLESHOOTING

FAULT
CAUSE
CORRECTIVE ACTION
Check the sensor electric connections.
Though UP or DOWN keys
Check if sensor operates properly.
If not, replace it.
are pressed, the instrument
doesn't receive any signal from
Check the position of sensor and magnet on
the magnetic sensor for more
gipsy and their distance (3 mm).
than 5 seconds.
V=11.6 Vdc
Check the operation of electric
installation or anchor windlass.
The instrument's power
Verify the battery charge or
operation of the electrics system.
supply voltage is lower than10Vdc.
V= 7.9 Vdc