Faber Hemmet Black Manual De Instrucciones página 6

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12
Faber Opti-myst Inset Fires
Model: Hemmet Black & Hemmet Brass
IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
Important Safety Advice:
When using electrical appliances, basic precautions should always be followed to reduce the
risk of fi re, electrical shock and injury to persons, including the following:
If the appliance is damaged, check with the supplier before installation and operation.
Do not use outdoors.
Do not use in the immediate surroundings of a bath, shower or swimming pool.
Do not locate the heater immediately below a fi xed socket outlet or connection box.
This appliance is not intended for use by children or other persons without assistance or
supervision if their physical, sensory or mental capabilities prevent them from using it
safely. Children should be supervised to ensure that they do not play with the appliance.
Do not use this heater in series with a thermal control, a program controller, a timer or any
other device that switches on the heat automatically, since a fi re risk exists when the heater
is accidentally covered or displaced.
Ensure that furniture, curtains or other combustible material are positioned no closer than 1
metre from the heater.
In the event of a fault unplug the heater.
Unplug the heater when not required for long periods.
Although this heater complies with safety standards, we do not recommend its use on deep
pile carpets or on long hair type of rugs.
The appliance must be positioned so that the plug is accessible.
If the supply cord is damaged it must be replaced by the manufacturer or service agent or a
similarly qualifi ed person in order to avoid a hazard.
Keep the supply cord away from the front of the heater.
WARNING: In order to avoid overheating, do not cover the heater. Do not place material or
garments on the heater, or obstruct the air circulation around the heater.
The heater carries the Warning symbol indicating that it must not be covered.
General.
Unpack the heater carefully and retain the packaging for possible future use, in the event of
moving or returning the fi re to your supplier. The Remote Control and batteries are packed
separately in the carton.
The fi re incorporates a fl ame eff ect, which can be used with or without heating, so that the
comforting eff ect may be enjoyed at any time of the year. Using the fl ame eff ect on its own only
requires little electricity.
The heater is designed for use inset into a 407mm (16") or 457mm (18") wide by 559mm (22") high
fi replace opening - see also section 'Installation Instructions' .
Before connecting the heater check that the supply voltage is the same as that stated on the heater.
Please note: Used in an environment where background noise is very low, it may be possible to hear
a sound which is related to the operation of the fl ame eff ect. This is normal and should not be a cause
for concern.
Electrical connection.
WARNING – THIS APPLIANCE MUST BE EARTHED.
This heater must be used on an AC ~ supply only and the voltage marked on the heater must
correspond to the supply voltage.
Before switching on, please read the safety warnings and operating instructions.
PLEASE RETAIN THIS USER'S GUIDE FOR FUTURE REFERENCE
Do not put Opti-myst plastic components into a dishwasher.
Only slide out the drawer when the water tank needs to be fi lled or a lamp needs to be changed
otherwise you will inadvertently alter the water level and the fl ame eff ect operation.
Only use fi ltered tap water in this appliance.
Always ensure that the appliance is sitting on a level fl oor.
If you intend not using the appliance for longer than 2 weeks, drain the water from sump and
water tank and dry the sump.
Once installed, never move this appliance or lay on its back, without draining the water from
sump and water tank.
The water tank, sump, sump lid, tank cap and air fi lters must be cleaned once every two weeks,
particularly in hard water areas.
The appliance should never be operated if the lamps are not working.
The lamps should be regularly inspected as described under 'Maintenance' and 'Changing
Lamps' .
Installation Instructions
Before installing this appliance, we recommend that;
1.
You have your chimney cleaned by a competent chimney sweep.
2.
You block off the chimney fl ue.
This procedure is important for the effi cient operation of the heating unit and will also reduce heat loss
up the chimney.
Installation.
Ensure that all packing items are removed (read any warning labels carefully).
Retain all packing for possible future use, in the event of moving or returning the appliance to
your supplier.
To install the appliance;
1.
Remove the fi replace grate, ashpan etc.
2.
The ashbed grate should be stored away for possible future use.
3.
Clean the hearth of any ash residue or dust etc.
At the rear of the appliance, two adjustable supports are provided for levelling, where the base of the
fi replace opening is raised above the level of the hearth.
You are now ready to install the electric fi re into your fi replace.
Make sure the unit is switched OFF.
Hold the fi re by the sides of surround and gently manoeuvre into position. Plug the fi re into a
13amp/240 volt outlet. Ensure that the supply cable exits at the front of the fi re, at the right or left
hand corner to suit your supply socket location and is not trapped under the fi re such that it might
cause it to be damaged.
Before using the manual controls fi rstly fi ll the water tank (See 'Maintenance' , 'Filling the water
tank').
Manual Controls.
The Opti-myst Manual controls are located beneath the hinged canopy cover. Raise the canopy cover
to access the controls. (See Fig. 2 for Manual Control lay out)
Switch 'A':- Controls the electricity supply to the heater.
Note: This switch must be in the 'ON' ( I ) position for the heater to operate with or without heat.
Switch 'B':- Controls the function of the fi re.
Press
once to turn on fl ame eff ect. This will be indicated by one beep.
Although the main lights operate immediately it will take a further 30 seconds before the fl ame
eff ect starts.
again to give fl ame eff ect and half heat. This will be indicated by two beeps.
Press
Press
again to give fl ame eff ect and full heat. This will be indicated by three beeps.
Press
again to return to fl ame eff ect only.
This will be indicated by one beep.
Press
to put fi re in to standby mode.
This will be indicated by one beep.
Control Knob 'C':- Controls the intensity of the fl ame eff ect.
Turning the control knob Clockwise increases the fl ame eff ect, turning the control knob Anti Clockwise
will decrease the fl ame eff ect.
Control Knob 'D':- Controls the Electronic Thermostat setting.
Turning the control knob Clockwise will decrease the temperature setting, turning the control knob
Anti Clockwise will increase the temperature setting.
When the water is empty the main lamps go out. See instructions under 'Maintenance' , 'Filling the
water tank' . When this procedure is complete, the main lamps will illuminate but it will take 30 seconds
before the fl ames return.
Electronic Thermostat
The thermostat controls the heat output according to the room temperature. This ensures that
the heater will not produce heat unnecessarily when the room is warm.
To set the temperature you require, turn the thermostat control knob 'D' (See Fig. 2) Anti-Clockwise
until the desired temperature is reached. Alternatively to heat a cold room quickly, turn the thermostat
control knob 'D' (See fi g. 2) up fully. When the room has reached the desired temperature, turn the
thermostat control knob 'D' (See Fig. 2) clockwise until the desired heat setting is achieved.
The heater will now automatically operate at this temperature.
Remote Control Operation
On the control panel, Switch A (see Fig. 2) must be in the 'ON' ( I ) position in order for the remote control
to operate. There are 3 buttons on the remote control. (See Fig. 7)
To operate correctly the remote must be pointed towards the front fuel eff ect.
The remote control functions are as follows:
Press once to turn on Flame eff ect only.
This will be indicated by one beep.
Press once to turn on Half heat and Flame eff ect.
This will be indicated by two beeps.
Press again to turn on Full heat and Flame eff ect.
This will be indicated by three beeps.
Standby
This will be indicated by one beep.
Battery Information.
1.
Unclip the battery cover on the back of the remote control. (See Fig. 7)
2.
Install AAA batteries into the remote control.
3.
Replace the battery cover.
Discard leaky batteries.
Dispose of batteries in the proper manner according to provincial and local regulations.
Any battery may leak electrolyte if mixed with a diff erent battery type, if inserted incorrectly, if all the
batteries are not replaced at the same time, if disposed of in a fi re, or if an attempt is made to charge a
battery not intended to be recharged.
Thermal safety cut-out
A thermal safety cut-out is incorporated in the fan heater to prevent damage due to overheating. This
can happen if the heat outlet was restricted in any way or if the chimney fl ue has not been blocked off
eff ectively. If the cut-out operates, unplug the heater from the socket outlet and allow approximately
10 minutes before reconnecting. Before switching the heater back on remove any obstruction that
may be restricting the heat outlet, then continue normal operation.
- 1 -

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Hemmet brass

Tabla de contenido