4. CONTROLS
(CONT'D)
4.4
O
A
PTIONAL
UXILIARY
4.4.1
20-M
L
INUTE
IGHTED
Set the push-button timer to ON. The fan motors will then operate at high speed for 20 minutes and the
indicator will light up.
To stop activation, push one time; the unit will then get back to previous selection.
4.4.2 60-M
C
INUTE
This control makes the system operate at high speed for periods varying from 10 to 60 minutes.
4.4.3 H
C
UMIDITY
ONTROL
Setting during the fall, winter and spring months:
Adjust knob to the desired maximum humidity level.
Setting during summer:
Adjust knob to the OFF positon.
Do not select a humidity level below 30%. This could lead to excessive dryness in
the air causing discomfort for the occupants.

5. ELECTRICAL CONNECTION TO THE FURNACE

Never connect a 120-volt AC circuit to the terminals of the furnace interlock (standard wiring). Only use the low
voltage class 2 circuit of the furnace blower control.
For a furnace connected to a cooling system:
On some older thermostats, energizing the "R" and "G" terminals at the furnace has the effect of energizing "Y" at the thermostat and
thereby turning on the cooling system. If you identify this type of thermostat, you must use the alternate furnace interlock wiring.
Standard furnace interlock wiring
W
R
G
Y
FOUR
WIRES
TWO WIRES
heating only
W
R
G
C
Y
FURNACE
24-VOLT
TERMINAL BLOCK
VE0108A
W
C
O
ALL
ONTROLS
PERATION
P
-B
T
USH
UTTON
IMER
T
RANK
IMER
CAUTION
THERMOSTAT
TERMINALS
TWO WIRES
COOLING SYSTEM
WARNING
!
0
Alternate furnace interlock wiring
4 WIRES
2 WIRES
heating only
W
R
R
G
C
Y
Y
FURNACE
24-VOLT
TERMINAL BLOCK
- 19 -
HUMIDITY
CONTROL
VC0085
THERMOSTAT
W
R
G
Y
TERMINAL
wiring
nuts
NO
NC
C
2 WIRES
ON
VC0084
OFF
TURN
PAST
20
10
20
30
60
40
50
VC0017
20%
25%
70%
30%
60%
50%
40%
COOLING SYSTEM

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Erv90hc serieHrv90htHrv90hsErv90hctErv90hcs

Tabla de contenido