Press OK for Start Calibration.
Follow the instructions given on the display and dip both sensors into the
·
appropriate buffer solution, first in one solution and then the other. The device will
carry out a two-point calibration for you, first calibrating with buffer solution 7.00,
then with buffer solution 4.00 (.never the other way round!). The temperature
is unimportant as it is measured by the temperature sensor and the temperature
influences are automatically compensated.
·
After successful calibration, "Calibration OK" will appear on the display.
·
Press OK to confirm.
·
Press the setting symbol. The value overview appears, giving information about the
most important values (chapter 4).
·
Dispose of the buffer solutions, briefly rinse the cuvettes in tap water and dry them
on paper kitchen roll.
Install the pH sensor in the darkest possible position with a good water flow in the aquarium.
The sensor can be immersed to a maximum of 2/3 of its length. The sensor cap with cable
must not be immersed in the water.
The temperature sensor can be attached at any position in the aquarium using the suction
pads provided. Now you can select your required settings on the menu (chapter 7.1 – 7.13).
Sleep mode and value overview
If no input is made, the device will switch into the sleep mode after about 30 seconds.
There the image of a water drop and the permanent information of the present pH and
temperature values appear. After tapping the screen the value overview will appear. It gives
information, as illustrated below, about the most important processes relating to the pH
value and the supply of CO₂ into the aquarium: