Illustration is for example only; your site may have
additional entrapment zones which MUST be protected.
Public Side
Place warning signs
on both sides of the
gate in clear view
Interior posts,
non-pinch rollers (2x)
Gap between vertical
bars MUST be less
than 2-1/4" (57 mm)
Edge sensor
Left hand
gate opening
Photoelectric sensor (open direction)
Illustration is for example only; your site may have
additional entrapment zones which MUST be protected.
Place the warning signs on both
sides of the gate in clear view
Earth ground
Pedestrian gate located near
the swing gate. Make sure a
separate pedestirian entrance
is available and the path is
clearly designated.
Earth ground
Photoelectric sensor (open direction)
Public Side
Photoelectric sensor
(public side)
Edge
sensor
Curb
Pedestrian gate located near the slide gate.
Make sure a separate pedestirian entrance is
available and the path is clearly designated.
6' (1.8 m)
minimum
Edge sensor
Photoelectric sensor
(close direction)
Edge sensor
Photoelectric sensor
(close direction)
Any gap larger than 2-1/4" (57 mm) between
gate and fixed objects MUST be protected.
Install edge sensors where gap between post
and gate creates a draw in zone.
Take a photograph of the complete installation site for your records
Mount access control devices at
least 6' (1.8 m) beyond the gate
Photoelectric sensor
(public side)
Photoelectric
sensor
Secure Side
Entrapment
zone
Cross Section
Secure Side
Reflector for
photoelectric
sensor
Curb
Take a photograph of the complete
installation site for your records