Maintenance And Storage - Master MAC-36-BDF Manual De Instrucciones

Ocultar thumbs Ver también para MAC-36-BDF:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1. Remove screws from Rear Guard and tilt wheel
(Figure 2).
2. Loosen motor nuts, and motor safeguards (located
above and below motor).
Figure 2: Removing Guard
1. Inspect your fan before each use. Check all wires and
extension cords, following the procedure outlined on
Page 1 (Safety Information).
Figure 4:
Capacitor Assembly
© 2018, Pinnacle Climate Technologies, Inc.
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING
OR WHILE CONNECTED TO A POWER SOURCE
Belt Tightening / Replacement

Maintenance and Storage

2
3. Remove belt to replace, or adjust motor to tighten belt
(Figure 3).
Figure 3:
Adjusting Fan Belt
2. After use, always be sure fan's Power Switch is in the
OFF position before unplugging. Use cord wrap (see
page 4 Item #5) to keep cord off the ground when
transporting fan.
Bearings
Figure 5: Fan Shaft Assembly
High Capacity Barrel Fan User's Manual
Bearing E-clips