www.mediclinics.com
'AIR UNIT' INSTALLATION M092A
Drill a 50mm hole on the wall.
A – Place the 'air unit' in the hole, inserting the IR sensor wire in advance.
C – Firmly hold the 'air unit' to ensure a correct placement, insert the washer, the earth
tag and firmly screw the 3 M6 nuts.
C – Move the bezel to completely hide the hole
'MOTOR UNIT' INSTALLATION
Carefully remove the casing since it is connected to the base by a tab that joins the two
pieces (casing and base) at the rear. Remove the casing keeping it at an angle at all
times (Figure 3) until the upper tab is completely withdrawn, taking care to not damage
the internal components, in particular the electronic circuit, and not damage the surface
of the casing. ATTENTION: WHEN THE CASING IS DISMANTLED ACTIVE PARTS
OF THE DEVICE BECOME ACCESSIBLE.
A - Make four drill holes with an 8 mm (0,31") diameter in the wall, using the provided
template.
B - Pass the electrical cables from the power grid through the hole with the 22 mm
(0,87") diameter which is situated above the device's terminal strip.
C - Firmly screw the base of the device to the wall, ensuring that the 4 silent- blocks
are correctly placed between the base and the wall
15