ACTUATOR FIXING
Choose measures referring to the table you can find in the
previous page, mark them on the pillars and continue as
follows:
• Fix brackets on the pillars and on the gate making use of
wedges. If structure and materials make it possible, you can
weld the brackets directly.
• Close the swing.
• Unlock the actuators.
• Position the actuators on the brackets.
• Insert the 2 pins in the special housing.
• Insert and screw the 2 grub screws with a 6mm allen
spanner.
• Open and close the swings repeatedly manually to verify the
absence of frictions between gate and ground.
WARNING: in order to avoid damage to the actuator,
please adhere to the following conditions:
• The brackets must be installed at the same height.
• The maximum stroke of arm A (in case of gate completely
closed) should not exceed 370mm for B300, 470 mm
for B400 and 670 mm for B600.
• The minimum stroke of arm B must be more than 70 mm (in
case of gate completely open).
WARNING: the brackets MUST be placed as shown by
the picture. Setting wrongly one single bracket can seriously
damage the motor.