led correctly. In this phase, the motors have less power and the way this parameter
GB
is set can infl uence the level of safety of the system itself. Once these parameters
have been regulated, check the force of impact of the gate leaves.
sbat
•
opening or closing) when the control board interprets the obstacles as a limit stop
and stops. The default space set by Stagnoli is 5cm and can be regulated from
1 to 10cm.
WARNING: The way this parameter is set can infl uence the level of safety of the
system itself. Installation must be carried out in compliance with the safety mea-
surements in order to keep this parameter as low as possible and to ensure the
safety of the system.
v rl
•
(slowing speed)= these are values that concern the speed with which the
motors operate in the slowing phase. The default value set by Stagnoli is 3 and it
can be regulated from 1 to 4, where the lowest value indicates low speed and 4
indicates a speed of approximately half the motor operating speed.
fm1a
•
(anti-crushing force of motor 1 in opening)= this is the anti-crushing force of
the fi rst leaf of the gate stated in percentage compared with the maximum force
that the same can generate. The default value set by Stagnoli is 50 and it can be
regulated from 20 to 99.
fm1c
•
(anti-crushing force of motor 1 in closing)= This is the anti-crushing force of
the fi rst leaf of the gate stated in percentage compared with the maximum force
that the same can generate. The default value set by Stagnoli is 50 and it can be
regulated from 20 to 99.
fm2a
•
(anti-crushing force of motor 2 in opening)= this is the anti-crushing force
of the second leaf of the gate stated in percentage compared with the maximum
force that the same can generate. The default value set by Stagnoli is 50 and it
can be regulated from 20 to 99.
fm2c
•
(anti-crushing force of motor 2 in closing)= This is the anti-crushing force
of the second leaf of the gate stated in percentage compared with the maximum
force that the same can generate. The default value set by Stagnoli is 50 and it
can be regulated from 20 to 99.
WARNING: The way these two parameters are set can infl uence the level of safety
of the system itself. Stagnoli advises setting this parameter with a safety margin
that is at least +10 compared with the maximum current consumed by the motors
in the opening and closing phases respectively. This is shown during the motor
stroke on the display in the second main screen.
fm1a
fm1c
,
vity.
At the end of installation check that the force of impact is in compliance with the
regulation EN12453.
tser
•
(electric lock activation time)= this is the time stated in seconds, going from
the time of total closure of the gate to the activation of the electro lock. The de-
fault value set by Stagnoli is 2 and it can be regulated from 0 to 7 seconds.
25
(striking space)= this is the space in centimetres before the strike (when
fm2a
fm2c
,
and
with low values indicate greater anti-crushing sensiti-