Product Dimensions 686 mm (27") dryer
686 mm
(27")
965 mm
(38")
25 mm
(1")
FRONT VIEW
ELECTRIC
102 mm (4")
BACK VIEW
736 mm
(29")
203 mm
(8")
921 mm
(36
1
/
")
4
25 mm
SIDE VIEW
(1")
159 mm
(6
1
/
")
4
715 mm
(28
1
/
")
8
89 mm
dia.
(3
1
/
")
2
358 mm
(14")
695 mm
(27
/
")
1
4
Electrical Requirements
This dryer is supplied without an electric cord and plug. It must
be connected by a competent electrician to a single-phase
electricity supply at the voltage shown on the dataplate, using a
suitable fixed wiring installation in accordance with local and
national wiring regulations.
I A 3-wire circular cord of minimum conconductor size 2.5 mm
cross-section area should be used.
I A 30A supply fuse should be used, and a switch having a
contact separation in both poles that provides full disconnection
under over-voltage category III conditions must be incorporated
into the fixed wiring in accordance with local wiring
regulations. The dryer should be positioned so that the
disconnection switch is clearly visible and easily accessible
to the user. This disconnection switch also provides the
function of an emergency stop control for the user.
I A cord clamp bush is provided on the dryer, and should be
tightened on completion of wiring. The electrical mains
terminals are located behind the small rear access panel
(terminal block cover), and connections should be made in
accordance with the terminal markings. Remember to replace
the terminal access panel (terminal block cover).
NOTE: In accordance with the European EMC Directive
(2004/108/EC), the maximum electricity supply system
impedance to which the electric dryer should be connected
is declared to be 0.054 Ohm + j0.034 Ohm.
NOTE: Electrical safety standards: The manufacturer has
chosen compliance with IEC/EN.60335 standards as the most
appropriate for this product.
This is a 3-wire appliance which must be earthed.
If codes permit and an additional earth bond wire is used, it is
recommended that a qualified electrician determine that the earth
bond path is adequate.
Recommended Earthing Method
I It is your responsibility to contact a qualified electrical installer
to ensure that the electrical installation is adequate and in
conformance with all local codes and ordinances.
2
5