quickly unplug the control cable from the rear of the rotator's controller box, and disconnect the AC cable from the wall
outlet. Disconnect the coaxial cable(s) from the antenna(s) as well. Do this only if the lightning is not in your immediate
area, as you could be killed instantly if lightning should strike while you are holding a cable.
If you have any doubts about your ability to install this rotator safely, enlist the services of a professional antenna
installation company.
Power Supply Voltage:
Power Supply Current Consumption:
Rotor Voltage:
360° Rotation Time (Non Loaded):
Rotation Range:
Rotation Torque (@230 VAC):
Braking Torque:
Maximum Vertical Load:
Mast Outside Diameter:
Braking Type:
Antenna K Coefficient:
Wind Loading Area:
Maximum Continuous Duty:
Operating Temperature Range:
Rotator Dimensions:
Rotator Weight:
Controller Dimensions:
Controller Weight:
This equipment complies with the following standard:
EMC Directive 89/336/EEC: EN50081-1 & EN50082-1
LVD 73/23 EEC: EN60065
Specifications are subject to change without notice.
G-1000DXC/-2800DXC User Manual
Specifications
G-1000DXC
220 – 240 VAC, 50 – 60 Hz
0.5 A
11 – 24 VDC
100 ± 10 sec to 40 ± 5 sec (Variable) 120 ± 10 sec to 50 ± 5 sec (Variable)
450° ± 3°
600 to 1,100 kgf-cm
6,000 kgf-cm
200 kg or less (continuous)
800 kg (momentary)
φ38 to φ63
Mechanical and Electrical stoppers
230 or less
0.75 m x 0.6 m or less (Pole Type)
2.2 m or less (Tower Type)
3 minutes
0 °C to +40 °C (Controller)
–20 °C to +40 °C (Rotator)
φ186 x 300 mm
Αpprox. 3.6 kg
200 (W) x 130 (H) x 193 (D) mm
Approx. 2.8 kg
Rotator Attachment Dimensions
G-2800DXC
220 – 240 VAC, 50 – 60 Hz
0.7 A
11 – 24 VDC
450° ± 3°
800 to 2,500 kgf-cm
25,000 kgf-cm
300 kg or less (continuous)
1,200 kg (momentary)
φ48 to φ63
Mechanical and Electrical stoppers
950 or less
1 m x 0.8 m or less (Pole Type)
3 m or less (Tower Type)
3 minutes
0 °C to +40 °C (Controller)
–20 °C to +40 °C (Rotator)
φ200 x 345 mm
Αpprox. 6.5 kg
200 (W) x 130 (H) x 193 (D) mm
Approx. 3.8 kg
Page 15