Bentel Security VRP-433 Instrucciones De Instalación página 6

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

The VRP-433 includes a Programming button
used to place it into Enroll/Placement modes.
A 4-position DIP switch is also provided to set
the following options:
Table 2: DIP Switch Settings
Switch
1
Wall tamper enabled Wall tamper
2
RF Jam notification
not sent to receiver
3
Compatible with
VRX32-433
receivers
4
For installations
with 1 VRP-433
The default for all switches is ON.
Install the VRP-433 in the following order.
NOTE: When enrolling and placement testing the VRP-433 with the alarm panel, refer to the
compatible control panel installation instructions for the appropriate programming sections.
Step 1: Temporarily Mounting the VRP-433
Select a suitable location for the VRP-433. Use the following list as a guide:
• Locate device near a power outlet
• Location should be free from vibration and shock
• Mount on a flat, stable surface
• Ideal location is mid-way between the wireless transmitter and receiver. The minimum distance
between the VRP-433 and the receiver should be no less than 1 meter (3.28 feet)
Do not permanently mount the VRP-433 until it has been placement tested. Temporarily
mount the unit using tape or other non-permanent, non-marking method. If the selected
location fails the placement test, the device must be repositioned.
Step 2: Connecting Power
Connect back-up battery first then AC.
To connect the battery:
1. Gently open front cover using small slotted screwdriver in holes provided (see Figure 3).
2. Attach battery cable to connector on PC board.
ON
disabled
RF Jam
notification sent
to receiver
Compatible with
future receivers
For installations
with Multiple
VRP-433 's
Figure 2: Internal Controls
OFF
Installation
3
DIP Switch
X
Programming
Button

Publicidad

Tabla de contenido
loading

Tabla de contenido