Bentel Security VRP-433 Instrucciones De Instalación página 9

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Step 6: Quick Enroll/Placement Testing Devices
Up to 164 1-way wireless devices can be enrolled on the VRP-433. During the first 4 hours of power
up, the VRP-433 can be placed into Enroll/Placement Test modes. After the 4 hour time-out, access
to these modes is denied and the unit must be powered up again to enter Enroll/Placement mode.
NOTE: the control panel's software cannot be used to enroll wireless devices on the VRP-433.
All wireless devices being enrolled on the VRP-433 must also be enrolled on the receiver/control
panel.
To both enroll and placement test a device at the same time:
1. Press and hold Programming button for 1 second. "Mode Entered" tone (1 long beep) sounds.
The VRP-433 is now in Enroll/Programming mode.
2. Trip and restore zone to be enrolled 3 times:
• Door and window contact - open/close or tamper/restore
• PIR and other stationary devices - tamper/restore
• Wireless key - 3 separate button presses
3. Red LED (X) flashes until zone is enrolled. Once VRP-433 has received signal from zone,
Green LED (
) lights for 1 second and sounder emits "Zone Enrolled" (low to high) tone.
NOTE:
• If another zone is tripped during the enroll sequence, the enroll process must be restarted
by tripping and restoring the appropriate zone 3 times.
• A VRP-433 can not enroll another VRP-433.
• Stationary (permanently mounted) devices should only be enrolled with one VRP-433. The
only exception is in Residential Fire installations, where smoke detectors that are enrolled with a
VRP-433 must be enrolled with at least two VRP-433's.
• Fobs may be enrolled with multiple VRP-433's.
• If an enrollment is attempted after all 164 device slots have been filled, the VRP-433 emits a 2-
second error tone and all three LEDs light for 20 seconds to indicate that no further devices may
be enrolled.
4. After zone is enrolled, trip again to perform placement test (to test the signal between the
wireless device and the VRP-433). Green LED flashes if signal is received.
• If "Good Zone Placement" tone (1 beep) sounds, device location is satisfactory and unit may be
permanently mounted.
• If "Bad Zone Placement" tone (3 beeps) sounds, reposition device and trip zone again. Continue
until "Good Zone Placement" (1 beep) tone sounds.
5. Repeat steps 2-4 to enroll and placement test other zones.
• To exit, press Programming button again for 1 second or place cover back on VRP-433. "Mode
Exited" (3 beeps) tone sounds.
NOTE: If the VRP-433 tone can not be heard while testing the device, set the alarm panel
into individual placement test mode using the VRP-433 serial number. The VRP-433
placement test results are sounded through the alarm panel siren.
• Although good results may be obtained on the VRP-433, bad results are still possible from the
alarm panel due to collisions.
• Subsequent violations from an enrolled zone while the VRP-433 is in programming mode will
initiate a placement test.
6

Publicidad

Tabla de contenido
loading

Tabla de contenido