The following are the menus which can be modified:
P0
- Timer (MIN and AUTO modes)
P1
- Timer (MAX mode)
A2
Centigrade
and
degrees
A3
- Offset
A4
- Max condenser fan speed
A5
– Battery saver value
Vm
Cut-out
0
9.8
1
10
2
10.2
3
10.4
4
10.6
5
10.8
6
11
7
11.2
8
11.4
9
11.6
In MIN and AUTO mode, the system's default setting is 6 hours of
continuous operation. The default value can be changed in this menu.
The choice range is between 1 and 99 hours.
In MAX mode, the system's default setting is 4 hours of continuous
operation. The default value can be changed in this menu. The choice
range is between 1 and 99 hours.
The system's default setting is Centigrade degrees. This menu allows
Fahrenheit
you to change the parameter to Fahrenheit degrees.
This refers to the temperature difference detected by the probe and the
temperature shown on the display. This menu allows you to change this
value from -9°C to +9°C with 1°C increments.
The cooling fan's speed is variable and depends on the operation of the
compressor. Its default setting is 100% of its operational power. Its
maximum speed can be reduced (for example if it is too loud) according
to the following table. Bold values are its default settings.
WARNING: if the selected speed value is too low, the compressor
may overheat and the device may shut itself down (see error table –
code E3   –  
E
4   –  
E
Level
Percentage
10
9
8
7
6
5
4
Its default setting is 10.8 Vdc (Cut-out) and 12 Vdc (Cut-in). This menu
allows to change the values according to the following table. Default
values are in bold.
12Vdc
Cut-in
12.5
5).
100%
90%
80%
70%
60%
50%
40%
12Vdc
Vm
Cut-out
10
9.8
11
10
12
10.2
13
10.4
14
10.6
15
10.8
16
11
17
11.2
18
11.4
19
11.6
39
Cut-in
12