1.6 Maintenance
1.7 Cleaning
18
1.5.2 Raising and lowering
• Press button S for five seconds until a number appears on the
control element.
• Press button or and hold down until the required position
has been reached. The number that lights up is the height in
centimetres. With customised designs, the height that is
displayed can differ from the actual height.
1.5.3 Save position
Positions can be saved on buttons 1, 2 and 3.
• Move to required height.
• Press button S.
• Press button on which to store the position (1, 2 or 3).
The height has been stored.
1.5.4 Move to position
• Press button S for five seconds until a number appears on the
control element.
• Press button 1, 2 or 3 and hold down until the required position
has been reached.
• The lift is maintenance-free. Maintenance and repair work and the application of
lubricants are not permitted.
• In the event of damage or malfunctions that cannot be remedied using the
measures in chapter "1.8 Troubleshooting and fault remedying", disconnect lift
from power supply and contact the manufacturer.
WARNING
Risk of short circuits and fire due to improper cleaning!
> Never clean the lift with liquids, damp cloths, cleaning agents
containing alcohol, solvents or thinners.
> Do not use high-pressure or steam cleaning equipment.
• Clean exterior surfaces of the lift with a dry, soft cotton cloth, if necessary.