1.8 Troubleshooting
and fault remedying

1.9 Reset

Lift does not move
"E-01" is displayed
Lift is not reacting
correctly after a power
failure
Lift does not move to
desired position
Lift is at a slight angle due
to mechanical influences
Other malfunctions
• Press button  on control element and hold down until lift
reaches the bottom.
• Press button  again for 10 seconds. The lift is reset.
If "-" cannot be seen: disconnect from power supply
and check all connections / wait for 10 minutes /
re-connect to power supply / "-" illuminates again /
press button S for five seconds until a number
appears on the control element.
If "-" can be seen: Check whether the movement is
being blocked by an object or the shut-off strip is
being blocked.
Loss of position, lower the lifting unit and perform a
reset (see "1.9 Reset").
Perform a reset (see "1.9 Reset").
Save position again (see "1.5.3 Save position").
Rectify mechanical influences. Move lift slowly
downwards. Both sides will align themselves
horizontally again in the lowest position. Then press
button  for 10 seconds (see "1.9 Reset").
Contact manufacturer (see last page for address) or
supplier.