1.
WARNINGS
Before attempting any work on the electronic equipment
(connections, maintenance), always turn off power
- Install, upstream of the system, a differential thermal breaker
with adequate tripping threshold.
- Always separate power cables from control and safety cables
(push-button, receiver, photocells, etc.). To avoid any electrical
disturbance, use separate sheaths or a screened cable (with
the screen earthed).
2.

TECHNICAL SPECIFICATIONS

Power supply voltage
Absorbed power
Motor max. load
Accessories max. current
Operating ambient temperature
Fuses
Function logics
Work time (time-out)
Pause time
Terminal board inputs
Terminal board outputs
Programmable functions
Learning functions
3.
LAYOUT AND COMPONENTS
1 2 3 4 5 6
1 2 3 4 5 6
Description of components
J1
inputs terminal board and power supply to accessories
J2
connector for radio receiver (see Note)
J3
(not used)
J4
motor terminal board
JS
230 Vac power supply terminal board
J6
limit-switch terminal board
LED
Signalling LEDs
SW1
programming key
TR1
transformer
F1
6.3A- 250 V (motor protection)
F2
self-resetting (accessories protection)
An RP2 type 2-channel receiver can be connected to the J2
connector, so that the OPEN and CLOSE facilities of the automated
system can be commanded directly with a 2-channel radio control.
If using a single-channel RP type receiver, only OPEN can be commanded.
CONTROL UNIT 540 BPR
230Vac (+6% -10%) - 50Hz
4 W
800 VA
200 mA
-20°C to +55°C
F1 = 6.3A-250V
F2 = self-resetting
B/C, B, C, EP , AP , P
default = B/C
Self-learning (0-10 min in 2.5 sec steps)
default = 10 min
Self-learning (0-5 min in 1.5 sec steps)
default = 30 sec
Open, Close, Stop,
Limit-switch, CL safety
devices, Power supply
Motor and power supply
to accessories
Logic
Work time, Pause time
Fig. 1
4.
CONNECTIONS
Other safety device
24 V
24 V
E. g.: a connection with 2 pairs of closure photocells and a safety
device with NC contact.
Description of terminal boards
Terminal
Description
1
OPEN
2
CLOSE
3
STOP
-
4
24Vdc
+
5
24Vdc
6
SAFETY
7
COM
8
FCA
9
FCC
10
COM
11
CL
12
OP
13 - 14
230 Vac - 50Hz
4
C
M
24 V
24 V
Fig. 2
Device connected
Device with N.O. contact
(see chap. FUNCTION LOGICS)
Device with N.O. contact
(see chap. FUNCTION LOGICS)
Device with N.C. contact
which causes the automated
system to lock
Power supply for accessories
Closure safety device with
N.C. contact (see chap.
FUNCTION LOGICS)
Limit switch common contact
Opening limit-switch
(N.C. contact)
Closure limit-switch
(N.C. contact)
Motor common contact
Motor closure stage
Motor opening stage
Board power supply