5.
PROGRAMMING THE FUNCTION LOGIC
To select the function logic, press the SW1 push-button the number
of times equal to the number of the required logic, irrespective of the
current logic and the door status. The interval between the pulses
must be less than 1 second.
The selected logic is then continuously displayed by the DL1 LED,
which flashes once a second at 3 sec intervals, equal to the number
of the required logic.
To select the logics, press SW1 the number of times indicated in the
table below:
No.
Logic
Description
B/C
1
Mixed B / C
(default)
2
B
Semiautomatic B
3
C
Manned
4
EP
Stepped semiautomatic
5
AP
Stepped automatic
6
P
Stepped automatic
7
A
Automatic
6.
START-UP

6.1. LEDS CHECK

The following table shows the status of the LEDs in relation to the
status of the inputs (the closed at rest automated system condition
is shown in bold).
Check the status of the signalling LEDs as per table below:
Operation of status signalling LEDs
LED
Description
ON (closed contact)
DL1
/
Flashing to indicate selected logic
DL2
FCA
Opening limit switch free
DL3
FCC
Closure limit switch free
DL4
OPEN
Command enabled
DL5
CLOSE
Command enabled
DL6
SAFETY
Safety devices disabled
DL7
STOP
Command disabled
6.2 TIME LEARNING
Time learning instructions:
1. make sure that the door is closed, that the closure limit-switch is
engaged (FCC LED OFF) and that the STOP and SAFETY LEDS are
lighted;
2. press SW1 and hold it down until the automated system begins
the opening operation;
3. the automated system will stop automatically when the opening
limit-switch is reached;
4. after the motor stops, the board begins to learn the extra work
time (time-out after which the board commands the motor to
stop if the stop limit-switch is not reached correctly). Wait for the
time you require (max= 10 min), and then press OPEN or SW1 to
save it;
5. if the AP logic is set, after completing the procedure at point 4,
the board starts to learn the pause time. Wait for the pause time
you require, and then press OPEN or SW1 again to save it (max
= 5 min) and the automated system will automatically begin to
close the door;
6. if, instead, a logic other than AP is set, the learning stops at point
4. To close the door, press OPEN or CLOSE, according to the
logic.
6.3 PRE-FLASHING
If you wish to increase the equipment's safety level, you can activate
the pre-flashing function which enables the flashing lamp to go on
3 seconds before the starts move.
Pre-flashing activation procedure:
1) check if the gate is closed
2) open and keep open the Stop contact
3) check if the DL1 LED is OFF (if lighted, pre-flashing is already
active)
4) briefly press the SW1 push-button and check if the DL1 LED
lights up.
SW1 PRESSINGS
5) close the Stop contact (DL1 goes OFF).
once
Procedure for disabling the function:
1) check if the gate is closed
twice
2) open and keep open the Stop contact
3 times
3) check if the DL1 LED is lighted (if OFF, pre-flashing is already
disabled)
4 times
4) briefly press the SW1 push-button and check if the DL1 LED is
5 times
OFF.
5) close the Stop contact
6 times
7.
7 times
When you have finished programming, check if the system is
operating correctly. In particular, check if the safety devices are
operating correctly.
OFF (Open contact)
Opening limit switch
engaged
Closing limit switch
engaged
Command disabled
Command disabled
Safety devices
engaged
Command enabled
5

AUTOMATED SYSTEM TEST