ENGLISH
Radiocoder LED does not light up);
• Move Tx closer to make contact with the
Radiocoder and press the channel for which the
serial code is to be acquired (if the reading is
not done within about 15 sec. an Err: message is
displayed; in such cases, press OK);
• If the reading has been done correctly, P8
appears on the display, then release the Tx key;
• Press OK, the procedure restarts proposing the
next Tx No.
P 9
TEACH SERIAL CODE TO TX
Transmits the serial code keyed in (6 alphanumeric
digits) to the Radiocoder for coding Tx.
• Enter the first two digits of the serial code
(alphanumeric values from 00 to FF);
• Press OK;
• Enter the second set of four digits of the serial
code
(alphanumeric values from 0000 to FFFF);
• Press OK: the serial code is transmitted by the
Radiocoder (the display shows four steady light
points and the Radiocoder LED lights up);
• Move the Tx closer to make contact with the
Radiocoder and press the channel on which the
serial code is to be stored, checking the double
flashing of the Tx LED (learning occurred);
• When operations are complete, press OK.
P 10
COPY MEMORY MODULE
Copy the MEX1 memory on MEX2 memory.
the operation overwrites the MEX2 memory
contents.
the copy includes the plant code, serial codes
and the password.
• When the function is confirmed, the contents of
MEX1 memory bank are copied on MEX2.
P1
ENABLE Tx
P2
DISABLE Tx
P3
DELETE Tx
P4
ENTER PLANT CODE
(FROM KEYBOARD)
P5
ENTER PLANT CODE
(FROM RADIOCODER)
P6
TEACH PLANT CODE
TO Tx
P7
ENTER NEW Tx
(FROM KEYBOARD)
P8
ENTER NEW TX
(FROM RADIOCODER)
P9
TEACH SERIAL CODE
TO Tx
P10 COPY MEMORY
MODULE
P11 ENTER/CHANGE
PASSWORD
P12 DELETE DECODER
P 11
Sets the password (4 alphanumeric digits).
the password is stored in each memory bank
present.
• Enter the four digits of the new password
(alphanumeric values from 0000 to FFFF);
• Press OK.
P 12
Completely deletes the memory banks present
(plant code, serial codes and password).
the delete function is always possible, even
without knowing the password set, if any.
• When the function is confirmed, P12 flashes;
• Press OK again to delete the Decoder: the
display shows four steady light points;
• at the same time, check to ensure that the
Decoder LED lights up for a few seconds;
• When the deletion is complete, the programmer
returns to stand-by.
SUGGESTIONS
• In the same plant, do not duplicate the Tx with
the same serial code;
• Do not store the same serial code in different
positions in the Decoder;
• The memory banks inserted in the Decoder must
have the same plant code and the same
password;
• If the functions protected by password are
accessed by initially keying in a password that is
different from that stored in the Decoder, an Err:
message is displayed;
• For each plant, file the data relative to codes, Tx
No. and password.
QUICK REFERENCE GUIDE
Enter Tx No.(4 decimal digits from 0000 to 1999) + OK
Enter Tx No.(4 decimal digits from 0000 to 1999) + OK
Enter Tx No.(4 decimal digits from 0000 to 1999) + OK
Enter plant code (4+4 alphanumeric digits) + OK-->
--> stores and transmits to Radiocoder
Waiting reading of master Tx by Radiocoder
Enter plant code (4+4 alphanumeric digits) + OK-->
--> transmits to Radiocoder
Enter Tx No.(4 decimal digits from 0000 to 1999) + OK;
Enter serial code (2+4 alphanumeric digits) + OK-->
--> stores and transmits to Radiocoder
Enter Tx No.(4 decimal numbers from 0000 to 1999) + OK-->
--> waiting reading of Tx by Radiocoder
Enter serial code (2+4 alphanumeric digits) + OK-->
--> transmits to Radiocoder
MEX1 is copied on MEX2
Enter new password (4 alphanumeric digits) + OK
P12 flashes: press OK to delete decoder
6
ENTER/CHANGE PASSWORD
DELETE DECODER
ENGLISH