The oil and water extractor should not be mounted on or near the air
compressor.
The temperature of air is greatly increased during compression. As the air
cools down to room temperature, in the air line, on its way to the Air Power
Tool, the moisture contained in it condenses. Thus, for maximum
effectiveness, the oil and water extractor should be mounted at some point
Pitch pipe back toward air receiver
Compressor unit
Drain
Daily
1756
SUGGESTED AIR LINE CONNECTION
PIPE SIZE, I.D. (Inches)
Air Flow
CFM
50
10
1/2"
20
3/4"
30
3/4"
40
1"
50
1"
70
1"
Oil and Water Extractor should be at least 25 ft. from the compressor. Further if possible.
AIR SPOT DRILL KIT WITH 5.5" DEEP
CLAMP AND 5 DRILL BITS
PRODUCT INFORMATION:
• 2 Speed
• Free Speed 2000 rpm
• Adjustable depth stop which allows you to drill out just the
spot weld and not the panel beneath
• Drills out the entire spot weld, eliminating the need for grinding
• Lower speed decreases heat and extends drill bit life
• Kit Includes:
• 1 - Air Spot Weld Drill with 8mm Drill Bit
• 1 - 5.5" Deep Clamp
• 4 - Drill Bits 2pcs. 6.5mm (#1720) and 2pcs. 8mm (#1721)
• 1 - In Line Oiler (#3000)
• 1 - 3 Way Swivel (#3SB10)
• 1 - Plastic Blow Molded Case
SPECIFICATIONS:
Drill Bit Size Chuck Capacity:
Free Speed:
Overall Length:
Net Weight:
Air Inlet Thread NPT:
Air Hose I.D. Size:
Avg. Air Consumption:
Air Pressure:
in the air supply system where the temperature of the compressed air in the
line is likely to be lowest. Air lines must be properly drained daily. Each low
point in an air line acts as a water trap. Such points should be fitted with an
easily accessible drain. See diagram below. Pitch all air lines back towards
the compressor so that condensed moisture will flow back into the air
receiver where it can be drained off. Drain daily.
Install drain at
Length of Pipe (feet)
each low point
150
200
100
3/4"
3/4"
3/4"
3/4"
3/4"
1"
1"
3/4"
1"
1"
1"
1"
1"
1"
1-1/4"
1-1/4"
1"
25 FEET OR MORE
Page 3
5/16"
1,600 - 2,000rpm
8-3/4" (222mm)
3lbs. (1.4kg)
1/4"
3/8" (10mm)
4cfm
90-120psi
Oil and Water
Extractor
Drain
Daily
Drain
Daily