Descargar Imprimir esta página

in-lite FISH EYE WALL Manual De Instrucciones página 5

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

EN
Connecting the fixture to 12 V
The already installed lamp means the fixture is immediately ready for
use. Therefore you do not need to install the lamp first.
Step 1
Remove the wall plate from the fixture by loosening the two Torx
screws. Make a hole for the cable of at least 13 mm at the location of
the square (A). Attach the wall plate to the surface using the screws
supplied and plugs if necessary (the threaded, projecting elements
should point downwards for mounting the Fish Eye on the underside).
(Fig. 1)
Step 2
Feed the connector for the fixture through the hole (A), place the
fixture over the wall plate and fix the fixture in place by tightening the
two Torx screws. (Fig. 2)
Step 3
Join the Easy-Lock connector to the main cable. (Fig. 3)
a. There are two cable grips. The grip with the wider recess fits the
10/2 main cable, the grip with the narrower recess fits the 14/2
main cable. Clamp the correct cable grip over the main cable.
b. Put the cable grip (with the cable underneath) in the Easy-Lock
connector.
c. Tighten the threaded cap on the Easy-Lock connector. This will
cause the contacts to be pushed through the insulation on the
cable. In tightening the cap, a little gel is applied to the contacts in
the Easy-Lock connector. This serves to protect the contacts
against moisture. A little gel may possibly come out of the Easy-
Lock connector: so after installation (and/or before a meal), wash
your hands with soap and water, and avoid the gel coming into
contact with your eyes.
Step 4
Connect the main cable to the fixture by connecting the mini connector.
(Fig. 4)
If the lamp does not work correctly, check that the Easy-Lock
connector is properly connected to the main cable. Do the same for
the miniconnector. Repeat steps 3 and 4. When the fixture is con-
nected to the main cable also check that the contacts of the Easy-Lock
connector are not bent. If you have any problems, contact your dealer.
General maintenance advice
We advise wiping the fixture down at least once a year using a clean
cloth and warm water.
Accessories
Accessories are available for this fixture. See www.in-lite.com.
EN
Connecting the fixture to 100-240 V
If you want to connect the fixture to a 100-240V power source, you
must use the separately available internal transformer. Your dealer
can advise you about this. The appliance should only be connected to
a 100-240V power source by an authorised installer.
Step 1
Remove the wall plate from the fixture by loosening the two Torx
screws. Make a hole for the cable of at least 13 mm at the location of
the square (A). Attach the wall plate to the surface using the screws
supplied and plugs if necessary (the threaded, projecting elements
should point downwards for mounting the Fish Eye on the underside).
(Fig. 1)
Step 2
Remove the top plate from the fitting by loosening the four socket
screws. Place the internal transformer in the fitting and then fix it in
place with the two screws supplied. (Fig. 1A) Attach the top plate by
tightening the four Torx screws. ATTENTION: Ensure that the rubber
seal is correctly positioned between the fitting and the top plate.
Step 3
Link the internal transformer to the fixture by connecting the mini-
connector. (Fig. 4)
Step 4
Thread the 100-240V power cable of the internal transformer through
the hole (A), place the fixture over the wall plate and fix the fixture in
place by tightening the two Torx screws. (Fig. 2)
Step 5
The appliance should only be connected to a 100-240V power source
by an authorised installer. See the manual that accompanies the inter-
nal transformer.
General maintenance advice
We advise wiping the fixture down at least once a year using a clean
cloth and warm water.
Important!
Before starting maintenance switch off the power.
Accessories
Accessories are available for this fixture. See www.in-lite.com.