Section 3. Installation
SIDE VIEW
4 ft.
Window
Exhaust Grill
(Vent)
Building
Rev. C 10-5-07
OUTDOOR INSTALLATION
VENTING GUIDELINES
4 ft.
3'
4'
4'
Force
Air Inlet
Vent Termination:
Must be at least 3 ft. above any forced
air inlet located within a 10 ft. radius.
Must be located 4 feet away from the building wall
openings, and at the following distances away from
any door, window, or gravity air inlet:
4 ft. below,
4 ft. horizontally
1 7
4'
Property Line
Figure 9.
P/N 472592